2.1 Intended use 2.2 Installation and startup 2.3 General safety instructions 2.4 Resistance to aggressive substances Hazardous voltage Getting Started 3.1 Overview BNI IOL-800-000-Z036 3.2 Overview BNI IOL-800-000-Z037 3.3 Mechanical connection 3.4 Electrical connection 3.5 Function ground 3.6 IO-Link connection...
Page 3
Balluff Network Interface / IO-Link BNI IOL-800-000-Z03x 5.3 Electrical data 5.4 Operating conditions 5.5 LED indicator Status LED Appendix 6.1 Product ordering code 6.2 Order information Included material www.balluff.com...
Cross-references indicate where additional information on the topic can be found. 1.3 Symbols Attention! This symbol indicates a security notice which must be observed. Note This symbol indicates general notes. Abbreviations Balluff Networking Interface Direct Parameter Page Electromagnetic Compatibility Function Earth IO-Link ISDU Indexed Service Data Unit 1.5 Deviating views...
Balluff Network Interface / IO-Link BNI IOL-800-000-Z03x Safety 2.1 Intended use This guide describes the Balluff BNI IOL-800-000-Z03x for the application as status light module. Hereby it is about an IO-Link device which communicates by means of IO-Link protocol with the superordinate IO-Link master assembly.
A standard 3 wire sensor cable is used for connecting to the host IO-Link master. Module versions Version Description 1 segment configurable signal light with runlight BNI IOL-800-000-Z036 mode and flexible mode. 1 segment configurable signal light with runlight BNI IOL-800-000-Z037 mode, flexible mode and buzzer. www.balluff.com...
Balluff Network Interface / IO-Link BNI IOL-800-000-Z03x Getting Started 3.7 Short description The functionality of the Balluff status light module can be controlled through process data of the and ISDU registers. It has three main mode of functionality: functionality ...
5 ms * by min. cycle time 4.2 Process data / The BNI IOL-800-000-Z036 and BNI IOL-800-000-Z037 Smart Light modules have 1 byte Output data output process data. The output process data has different meaning depending on the selected mode (segment mode, runlight mode or flexible mode).
Balluff / IO-Link BNI IOL-800-000-Z03x IO-Link Interface BNI IOL-800- Byte 000-Z03x, Runlight Mode Bit definitions Bit 7, Buzzer state Bit 5/6, Sync start/Sync impulse in runlight (Only in case of BNI IOL-800-000-Z037) (available from software version 3.0) mode 0 – buzzer is off These bits are rising edge sensitive 1 –...
Balluff / IO-Link BNI IOL-800-000-Z03x IO-Link Interface Mode The operating mode of the Smart Light can be selected in the Mode ISDU register. 0 = Segment mode 2 = Runlight mode Runlight mode, Byte background color The background of the runlight effect can be set in this register.
0, 1, 2 or 3. Reading/writing the subindex 0 the whole 3 byte brightness data can be accessed. Subindex 1, 2 and 3 contains the brightness data for red, green and blue channels. Byte Index Brightness value for red Brightness value for green Brightness value for blue channel channel channel www.balluff.com...
Balluff / IO-Link BNI IOL-800-000-Z03x IO-Link Interface Blinking The frequency of the blinking in segment mode and the speed of the running segment in frequency / runlight mode can be set in this register. Values between 1 and 5 are accepted. One means the Runlight slowest and five means the fastest blinking or running speed.
BNI IOL-800-000-Z036 ca. 320 g Weight BNI IOL-800-000-Z037 ca. 390 g Dimensions BNI IOL-800-000-Z036: 117 × 60 × 60 mm (L × W × H, excluding connector) BNI IOL-800-000-Z037: 138,5 × 60 × 60 mm 5.3 Electrical data Operating voltage 18 ...
The status LED indicates the current status of the power supply and the communication. It can be switched on, switched of and flashing. Communication error Communication ok LED is flashing Supply modul LED is static off undervoltage LED is flashing Supply module ok LED is static on www.balluff.com...