HP 182C Operating And Service Manual page 33

Table of Contents

Advertisement

Model
182C
Adjustments
5-26.
HIGH
VOLTAGE POWER
SUPPLY ADJUSTMENT.
a.
The
required high voltage
output
of the
supply
is
-3150V
±0.5%.
b.
Using
1000:1
Divider Probe,
monitor
voltage
at
—100V
test
point
A1
A2TP4
with
Digital
Voltmeter.
c.
Note
voltage
reading
which
will
be approximately
O.IOOV. Accuracy
in
noting the voltage
is
essential for
proper adjustment.
d.
Multiply reading
obtained
in
step
c
by
31.50.
This
voltage
is
dangerous
to
life.
e.
Using 1000:1 Divider Probe,
monitor
high voltage
at
—3150V
test
point
A6TP1
with
Digital
Voltmeter.
f.
Set
High Voltage
adj
A10R3
to
obtain
reading
exactly equivalent to
result
obtained
in
step
d
(approxi-
mately
-3.150V).
5-27.
INTENSITY
LIMIT
ADJUSTMENT.
a.
Set
DISPLAY
to
EXT.
b.
Set
INTENSITY
control
to
center
(12
o'clock)
position.
c.
Adjust
Intensity
Limit
Adj
A6R2
to
just
extinguish
spot.
S28.
ASTIGMATISM ADJUSTMENT.
3.
Set
DISPLAY
to
EXT.
b.
Center
low
intensity
spot
with
HORIZONTAL
and
Vertical
POSITION
controls.
c.
Adjust
FOCUS
and
ASTIG
front-panel screwdriver
adjustment
for smallest
round
spot.
5-29.
FLOOD GUN
ADJUSTMENT.
a.
Set
INTENSITY
fully
ccw.
b.
Set
SCALE
fully
cw,
c.
Adjust
SCALE PATTERN ADJ A2R4
for
uniform
Illumination
Intensity.
d.
Slowly
rotate
SCALE
control while adjusting
SCALE
PATTERN
ADJ A2R4
as
necessary to
maintain uniform
illumination intensity
throughout
entire
range of
SCALE.
5-30.
TRACE ALIGNMENT ADJUSTMENT.
a.
Set
MAGNIFIER
to
XI.
b.
Set
EXT COUPLING
to
AC.
c.
Connect
Oscillator
400
Hz 10V
output
to
EXT
INPUT.
d.
Position trace
on
center horizontal
graticule
line
e.
Set
INTENSITY
and
FOCUS
to
view
sharply defined
trace.
f.
Adjust
TRACE
ALIGN
front-panel screwdriver
ad-
justment
A2R23
to
align
trace
parallel
to horizontal
graticule
line.
g.
Connect
Oscillator
400 Hz 10V
output
to Vertical
plug-in.
h.
Set
Vertical
plug-in
controls
to
obtain
vertical
trace.
i.
Adjust
Y ALIGN
adj
A5R61
to
align vertical
trace
parallel
to vertical graticule
line.
Note
Exact adjustment
is
very
important
if
repeatable risetimes
are to
be
ob-
tained
inboth-rUP and
—UP
operation.
j.
Disconnect
Oscillator
from
Vertical plug-in input.
5-31.
GATE
AMPLIFIER RESPONSE ADJUSTMENT,
a.
Set following controls
as applicable:
DISPLAY
INT
Main Time/Div
0.1
^.iscc
Main
Vernier
CAL
Sweep
Mode
AUTO
Sweep
Display
MAIN
Delayed Time/Div
OFF
h.
Set
Monitor
Oscilloscope controls
as follows:
Volls/Div
2
Time/Div
0,1
psec
Trigger
Source
INT
Slope
+
Coupling
DC
c.
Using 50:1 Divider
Probe and Monitor
Oscilloscope,
observe
signal
at collector of
A7Q8.
5-5