Optional–Attaching Tetra Contour to Tetra Contour LS
White wire with
red stripe
Tetra Contour LS
Tetra Contour LS can be connected to formable Tetra
1
Contour for custom shapes. Separate wires and identify
conductors as positive (+) and negative (–). Strip ends back
0.5 in. (13mm).

Troubleshooting

Symptom
Condition
All LEDs are OFF
No AC input.
Incorrect wire attachment.
Some LEDs
Overload (maximum load exceeded).
appear dim
Maximum recommended supply wire
length exceeded.
Mixed Suffix Codes of LED light engine
within an application.
Some of the sections are
Incorrect wire attachment.
not illuminated
Light/dark banding
LED light engine stretched during installation.
along a section
RISK OF ELECTRIC SHOCK:
Turn power OFF before inspection, installation or removal.
roperly ground Tetra Power Supply enclosure.
wer at fuse box or circuit breaker before installation.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [ A ] est conforme à la NMB-005 du Canada.
GE Lighting Solutions
GE Lighting Solutions is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
+ –
+
+
Tetra Contour
Conforms to the following standards:
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
Center wire (-)
White wire (-)
Tetra Contour LS
Splice the white wire with red stripe (+) of Tetra Contour LS
2
to the two outside wires (+) of Tetra Contour and splice the
white wire (-) of Tetra Contour LS to the center wire (-) of
Tetra Contour. Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
Solution
Attach AC input and/or check circuit breaker.
Check wire connection(s) at the Tetra Contour LED light engine and
power supply for improper connections or short circuits. Make sure you
have positive to positive and negative to negative wire connections.
Ensure the overall length of Tetra Contour LED light engine does not
exceed the maximum load as detailed in the Tetra Power Supply
Installation Instructions.
Reduce the length of supply wire equal to or below the
recommended maximum.
Make sure that all LED light engines have the same Suffix Code (Suffix
Code is located on each packaging label).
Check the wire connections at the Tetra Contour LED light engine for
improper connections. Make sure you have positive to positive and
negative to negative wire connections. Check for improper cutting
resolution locations (see Method B step 2).
Remove LED light engine and properly install.
RISK OF FIRE:
.
roved wire for input/output connections. Minimum size 18 AWG (0.82mm
Y-GE-LED
ww.gelightingsolutions.com
White wire with red stripe (+)
Outside wires (+)
Tetra Contour
ARCH002-R120210
2
)