11. Lubricate the wiper blade with lubricating powder and install with the two Phillips screws.
12. Wipe the PCR surface with a soft cloth to remove all traces of toner, and if need be, use a PCR cleaning liquid. Most marks
and even fingerprints can be removed with a damp cloth containing a few drops of neutral detergent and fractioning the surface
with axial strokes. Then, use a damp cloth to remove the rest of detergent and dry completely before installing the PCR. Clean the
PCR saddles with isopropyl alcohol and apply a slight coating of conductive grease to both ends. Continue to install the PCR
observing the proper location of each saddle. The green end to the right saddle and the white end to the left saddle.