Download Print this page

NAS E8 Installation Manual

Arm gate motor and control panel

Advertisement

Quick Links

E8 Arm Gate Motor and Control
Panel Installation Guide
Important Safety Information, Important Observations.............
Specification, Standard Packing ............................................
Gate Post Positioning, Gate Preparation, Installation Pointers......... 4
Installing Gate Post Brackets and the Arms (Pull-to-Open)............. 5
Push-to-Open, Non-Parallel of Gate and Arms............................. 7
Mounting of the Control Panel Box,
Connection of Power Source, Connection and Mounting of Battery .. 8
Control Panel – Model D1, DIP Switch Setting
Setting the System
Double Gate Operation
Single Gate Operation
Remote Control
Adding Remotes, Changing Remote Codes, Increasing Range
Other Consideration
Gate Stop, Wiring, Drain Hole, Motor Rotation,
Safety Beam, Lock
External Light Connection ................................................... 14
Troubleshooting
D1 Board Diagram
Transformer Power ....................................................
Limited Warranty
E8 Swing Automatic Gate. Revision 1.1.8 –1112
Contents
........................................... 10
........................................... 11
.................................................... 12
.................................................... 13
............................................................. 15
................................................................................. 18
1 of 19
......................... 9
2
3
17

Advertisement

loading

Summary of Contents for NAS E8

  • Page 1 ……………………………………………. 13 Gate Stop, Wiring, Drain Hole, Motor Rotation, Safety Beam, Lock External Light Connection ……………..……………………………. 14 Troubleshooting ……………………………………………………. 15 D1 Board Diagram Transformer Power ……………………………………………. Limited Warranty ................. 18 E8 Swing Automatic Gate. Revision 1.1.8 –1112 1 of 19...
  • Page 2: Important Safety Information

    Swing Gate Motor – Model E8 Arm E8 Swing Gate Motor is suitable for Light – Medium weight gates. Do not use it on large sized gate which exceed the maximum recommended gate weight. Wrong selection of motor will result in unreliable operation.
  • Page 3 : 2pcs Backup Battery 12V 7AH : 1pcs Floor Rubber Stopper : 1pcs Remote Control 3 + 1 : 1pcs Gate Taps for Stopper : 2pcs Release Key : 2pcs E8 Swing Automatic Gate. Revision 1.1.8 –1112 3 of 19...
  • Page 4 Hint : It’s best to locate the gate opener arms in approximately the middle between the top and bottom of the gate. This will prevent the gate from twisting and flexing. E8 Swing Automatic Gate. Revision 1.1.8 –1112 4 of 19...
  • Page 5 This marks the position of the gate bracket.  Extend the Arms to close the gates.  To extend the Arms use the backup battery supplied in your packing. E8 Swing Automatic Gate. Revision 1.1.8 –1112 5 of 19...
  • Page 6  Once the final position of the gate post has been determined, secure the gate post brackets onto the pillar(s).  Repeat the same procedure for the second gate leaf (Double). E8 Swing Automatic Gate. Revision 1.1.8 –1112 6 of 19...
  • Page 7 When the gate is Fully Opened or Fully Closed, the Arms must NOT be parallel with the gate. Gate and Arms Must NOT be Parallel Shown here is the Pull-To-Open Setup in the Fully-Opened position E8 Swing Automatic Gate. Revision 1.1.8 –1112 7 of 19...
  • Page 8 Battery Terminal on the Bottom. Shown here installation of 7AH Battery Mounting of Battery in Control Panel Box Z Metal Battery Holding Bracket E8 Swing Automatic Gate. Revision 1.1.8 –1112 8 of 19...
  • Page 9 Control Panel – Model D1 The E8 D1 control panel is specially designed to match 12Vdc Arm Gate Motor(s). The electronic panel requires no maintenance as long as the gate operates in proper order and is kept dry and insect free. Mount the Control box as close to the motor(s) (maximum 10m cable) as possible connected with minimum 1.5mm 2-core electrical...
  • Page 10 Note : For Pull to Open Gate – Arm is fully extended in the gate-close position For Push to Open Gate – Arm is fully retracted in the gate-close position E8 Swing Automatic Gate. Revision 1.1.8 –1112 10 of 19...
  • Page 11 / closing of the system. Setup is now complete. 7. Test each cycle a few times to make sure the microprocessor has stored the correct range. E8 Swing Automatic Gate. Revision 1.1.8 –1112 11 of 19...
  • Page 12 Place as high as possible in sight of the area you wish to transmit from. You can relocate the transmitter box to another moisture-free location to increase signal strength using cat.5 network cable. E8 Swing Automatic Gate. Revision 1.1.8 –1112 12 of 19...
  • Page 13 Connect to solenoid lock cables to the [LOCK] terminals on the D1 board. Set DIP switch [1] & [2] to ON position. This allows for the gate to have a slight reverse movement just prior to the disengaging of the solenoid lock. E8 Swing Automatic Gate. Revision 1.1.8 –1112 13 of 19...
  • Page 14 Dark Tape to cover the Lamp Photocell or turn the Photocell inwards when mounted in the Control Box. Point the lamp photocell to the side Gills of the supplied box for ambient light detection. E8 Swing Automatic Gate. Revision 1.1.8 –1112 14 of 19...
  • Page 15 As self- opening or self-closing gate is a poorly constructed gate. Such a gate will cause an uneven force for opening and closing stroke. E8 Swing Automatic Gate. Revision 1.1.8 –1112 15 of 19...
  • Page 16  System is running on battery only (eg. Solar setup) and transformer AC not connected. Check power with voltmeter. (does not apply to Version 1.3.0 chip. In Version 1.3.0 chip both gates will always close simultaneously even when running on Battery mode) E8 Swing Automatic Gate. Revision 1.1.8 –1112 16 of 19...
  • Page 17 [7] ON & [8] ON = 120 Sec. Auto Close and Yellow together in the [1/2] IMPORTANT NOTE : TRANSFORMER, BATTERY AND REMOTE RECEIVER MUST BE KEPT IN THE CONTROL PANEL BOX, OUT OF WEATHER E8 Swing Automatic Gate. Revision 1.1.8 –1112 17 of 19...
  • Page 18: Limited Warranty

    During the warranty period, E8 shall, as its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials. Any replacement and/or repaired parts are warranted for the remainder of the original warranty or ninety (90) days, whichever is longer.
  • Page 19 Regardless of its capabilities, an auto gate system is not a substitute for property of life insurance. An auto gate system also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation. E8 Swing Automatic Gate. Revision 1.1.8 –1112 19 of 19...