6) The cooling and sealing bar pressure will also need to be released follow procedure
1.6 and figure 3 for details.
7) Remove the old bands and clear any band fragments that may be present. This is also
an ideal time to clean the seal bars, refer to section 3.2 for information.
8) Place the new bands between the heating and cooling bars. This is accomplished by
gently pulling up on the pressure plates shown in Figure #5, then sliding the Teflon
band between the front and the rear sealing/cooling bars.
ORIGINAL INSTRUCTIONS
MPS6100-M MAINTENANCE MANUAL
Tension Knobs
FIGURE - 4
Page 8