Model 77 Series IV
Users Manual
Function
AC Volts (Average
6.000 V
responding)
60.00 V
600.0 V
1000 V
DC mV
600.0 mV
DC Volts
6.000 V
60.00 V
600.0 V
1000 V
600 Ω
Continuity
600.0 Ω
Ohms
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
50.00 MΩ
Diode test
2.400 V
Capacitance
1000 nF
10.00 μF
100.0 μF
9999 μF
AC Amps (Average
60.00 mA
[2]
responding)
400.0 mA
6.000 A
10.00 A
In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
[1]
[2]
Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A.
[3]
400.0 mA accuracy specified up to 600 mA overload.
[4]
>10 A unspecified.
12
info@Fluke-Direct.com
Range
Resolution
0.001 V
0.01 V
0.1 V
1 V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
1 Ω
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.001 V
1 nF
0.01 μF
0.1 μF
1 μF
[
1]
0.01 mA
[3]
0.1 mA
0.001 A
[4]
0.01 A
Fluke-Direct
Accuracy ± ( [ % of Reading ] + [ Counts ] )
2.0 % + 2
(45 Hz to 1 kHz)
0.3 % + 1
0.3 % + 1
Meter beeps at <25 Ω, beeper turns off at >250 Ω;
detects opens or shorts of 250 μs or longer.
0.5 % + 2
0.5 % + 1
0.5 % + 1
0.5 % + 1
0.5 % + 1
2.0 % + 1
1 % + 2
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
2.5 % + 2
(45 Hz to 1 kHz)