Teledyne MVX-7100 mL Installation Manual

Workstation plug-in for agilent masshunter workstation software

Advertisement

MVX-7100
µL
Workstation Plug-In
For Agilent MassHunter™ Workstation Software

Installation Guide

Manual Part Number 32-0059-048 Rev 0, April 3, 2017

Advertisement

Table of Contents
loading

Summary of Contents for Teledyne MVX-7100 mL

  • Page 1: Installation Guide

    MVX-7100 µL Workstation Plug-In For Agilent MassHunter™ Workstation Software Installation Guide Manual Part Number 32-0059-048 Rev 0, April 3, 2017...
  • Page 2 © 2017 Teledyne Technologies Incorporated. Windows is a registered trademark of COPYRIGHT TRADEMARK ACKNOWLEDGEMENTS All rights reserved. Microsoft Corporation in the United States and other countries. 32-0059-048 Rev 0, April 3, 2017, MassHunter is a trademark of Agilent Teledyne CETAC Technologies authorizes its Technologies Inc.
  • Page 3 Contents Overview............................ 4 Introduction ......................4 Requirements .......................... 4 Where to Go for More Information................5 Setting Up the Hardware ..................6 Installing the Plug-In......................7 Installing and Configuring the Plug-In ............7 Opening the Hardware Configuration Window ............8 Configuring the COM Port ....................9 Determining Which COM Port To Use..............
  • Page 4: Requirements

    1 Introduction Overview Use the Teledyne CETAC Technologies autosampler plug-in to operate a CETAC MVX-7100 µL workstation with the Agilent MassHunter™ Workstation software. Without the plug-in, the MVX-7100 workstation must be controlled by the CETAC Workstation software. With the plug-in, however, you do not need to use the CETAC Workstation software.
  • Page 5: Where To Go For More Information

    In addition to this manual, you can refer to the following resources:  The CETAC MVX-7100 µL Workstation Operator’s Manual provides information about installing and maintaining the MVX-7100 µL workstation.  Teledyne CETAC Technologies Customer Service and Support: Phone: 1 (800) 369-2822 (USA only) 1 (402) 733-2829 Fax: 1 (402) 733-1932...
  • Page 6: Setting Up The Hardware

    2 Setting Up the Hardware You will need to install the plug-in before you can complete setting up the MVX-7100 µL workstation. This is because the syringes pumps need to be at the 1/2 position in order to install the syringe barrels. If necessary, you can use the Direct Controls in the plug-in to move the syringe pumps to the proper position.
  • Page 7 3 Installing and Configuring the Plug-In Before you can create or run any methods with the MVX-7100 workstation, you must install the plug-in and configure it for your hardware. The plug-in reads the configuration information from when it is started. Under Mainframe Properties>External Device, there is a listing for the MVX- 7100.
  • Page 8: Opening The Hardware Configuration Window

    MVX-7100 Plug-In for MassHunter Chapter 3: Installing and Configuring the Plug-In Under Autosampler(ALS), click Properties and set the autosampler type to MVX-7100. The autosampler will appear in the list of hardware: If the plug-in does not appear in MassHunter, check that the MassHunter software was installed in the default location.
  • Page 9: Configuring The Com Port

    MVX-7100 Plug-In for MassHunter Chapter 3: Installing and Configuring the Plug-In Configuring the COM Port The plug-in will need to know which COM port is connected to the autosampler. If you are using a USB connection, the COM port numbers were assigned by the Determining Which COM Port To Use Windows when you connected the USB cables for the first time.
  • Page 10 MVX-7100 Plug-In for MassHunter Chapter 3: Installing and Configuring the Plug-In Configuring the COM Port Number In the hardware configuration window, click the COM Port tab. Select the COM port number from the list. Enable Auto Connect. When Auto Connect is enabled, the plug-in will automatically connect to the chosen COM port every time it is started.

Table of Contents