  • Page 1 G S M G a t e C o n t r o l G S M G a t e C o n t r o l G S M G a t e C o n t r o l AVG064 Integrated GSM module for Access Control Installation and Operation Manual Version 2.50...
  • Page 2 Cable, three wires cable for power and outputs. Power supply is not included. For power supply the AV-20 wall plug type, or the AV-21 are compatible, both 12V 1A DC. The AVG064 support up to 64 accounts for gate or door opening, or use the “Open to all feature” (#ACM command).
  • Page 3 Starting and Wiring Before setting the AVG064, get a GSM phone and an extra SIM card to insert into the AVG064. The SIM and GSM phone should be SMS and ID numbers enabled. Figure 2: AVG064 SIM card and LED’s The GSM phone is your programmer.
  • Page 4 #PWD: Password #WHL: White List (adds or removes numbers) You could also use the following, though not necessarily: #ACM: Access Mode #CAP: Change password #GOT: Gate pulse time #CSQ: Check Signal Quality Once you issue a command with an SMS, you will receive a confirmation SMS with OK if everything is correct or Error if there is an error.
  • Page 5 One of the most important functions is to receive alarms. In order to do this properly, you must turn on the function of the input and tell the AVG064 which are the recipient numbers and who should receive the alert message for the particular input.
  • Page 6 Administrator Number The 8 administrator numbers can be programmed with a text command via SMS. #TEL[N]=XXXXXXXXXX N stands for administrator number 1 – 8 (position) XXXXXXXXXX stands for the phone number you want to program as administrator. To add a number, the syntax of the command is the following: #PWD123456#TEL1=3593334444 Please note that it is possible to program up to a maximum of 16 digits for a number.
  • Page 7 Enabling input function To turn on the function of input, you can send the following commands by SMS message to the unit. #CTR=X X stands for ON (1) or OFF (0) value To turn on the input, the syntax of the command is the following: # PWD123456#CTR=1 Setting the Counter Alert Value For Input An alert message will be sent when the increment of alarm counter reaches the alert value...
  • Page 8 Function 3: Functions as counter. Activates the output relay 2 to stay on. Sends an alert message once triggered. Sends a counter alert message once the alarm counter reaches the alert value. Function 4: Functions as counter. Activates the output relay 2 for 1 second. Sends a counter alert message once the alarm counter reaches the alert value.
  • Page 9 Counter Resetting To reset the total counter value; send the following SMS message: #CLA The syntax of the command is the following: #PWD123456#CLA Output Settings To activate the output relay, send a text command via SMS specifying the number of seconds the output should stay on to the unit.
  • Page 10 Function Descriptions Function 0: This function is disabled ~ Normal Mode (Default) Function 1: Relay 1 will turn off for 10 seconds and turn on again. After 30 seconds, Relay 2 will be off for 5 seconds and turn on again. Function 2: At a programmable time section, Relay 1 or 2 will turn off for a programmable time (in seconds) and turn on again.
  • Page 11 #TSET=SS,MM,HH SS stands for 2 digits value: Seconds MM stands for 2 digits value: Minutes HH stands for 2 digits value: Hour Note: Time setting is necessary for operating function 2 at 5.3.1 Relay mode – Voltage on contact Mode To set the output relay 2 to supply voltage when activated, please adjust the jumper according to the diagram below: To set the output relay 2 to supply dry contact when activated, please adjust the jumper...
  • Page 12 Av-Gad is not an insurer of either the property or safety of the user’s employees, family, or 3rd part and limits its liability for any loss or damage including incidental or consequential damages to Av-Gad original selling price of the...