Download Print this page

Sony MDS-E12 Manual page 27

Rs-232c interface of mini disc recorder
Hide thumbs Also See for MDS-E12:

Advertisement

Example of transmission packet:
6.29
MODEL REQUEST
Function:
Data length:
Data:
Details of function:
Example of transmission packet:
6.30
STATUS REQ
Function:
Data length:
Data:
Details of function:
Example of transmission packet:
cause malfunction such that MDS sends out an incorrect track num-
ber.
Cancel edit operation just before the current operation.
7EH, 07H, 05H, 47H, 0AH, 11H, FFH
To check model information.
2 bytes
02H, 10H
Information about recording function of MDS can be shown by this
command.
Check model information.
7EH, 07H, 05H, 47H, 20H, 10H, FFH
To check the condition of mecha deck.
2 bytes
20H, 20H
This is the command to make MDS send out "STATUS DATA" indicat-
ing current mecha deck condition.
When this command is sent, MDS sends out "STATUS DATA".
"STATUS DATA" contains information such as exist/no exist of disc,
the value of REPEAT MODE, the value of PLAY MODE and so on.
Make MDS send out "STATUS DATA".
7EH, 07H, 05H, 47H, 20H, 20H, FFH