Toshiba RAS-B10SKVP-E Service Manual page 60

Hide thumbs Also See for RAS-B10SKVP-E:
Table of Contents

Advertisement

Terminal cover
Screw
Cord clamp
Earth screw
Connecting cable
10mm
NOTE :
• Connecting cable (Indoor unit/outdoor unit)
• Wire type: H07RN-F or 60245IEC66 (1.0 mm²)
More user manuals on
Screw
Terminal block
Earth wire
Connecting cable
Fig. 10-3-6
Terminal block
Earth wire (loop)
Fig. 10-3-7
About 15 cm
Fig. 10-3-8
110mm
10mm
50mm
Fig. 10-3-9
ManualsBase.com
10-3-5. Piping and Drain Hose Installation
Piping and drain hose forming
• Since condensation results in machine trouble,
make sure to insulate both the connecting pipes
separately.
(Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
1. Die-cutting front panel slit
Cut out the slit on the left or right side of the front
panel for the left or right connection and the slit
on the bottom left or right side of the front panel
for the bottom left or right connection with a pair
of nippers.
2. Changing drain hose
For left connection, left-bottom connection and
rear-left connection's piping, it is necessary to
relocate the drain hose and drain cap.
How to remove the drain cap
Clip drain cap with needle-nose pliers, and pull out.
Earth line
How to remove the drain hose
The drain hose is secured in place by a screw.
Remove the screw securing the drain hose, then
pull out the drain hose.
– 60 –
Fig. 10-3-10
Fig. 10-3-11
Screw
Drain hose
Fig. 10-3-12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents