Set Temp. Correction - Toshiba RAS-B10SKVP-E Service Manual

Hide thumbs Also See for RAS-B10SKVP-E:
Table of Contents

Advertisement

Item
18. Set temp.
correction
More user manuals on
Operation flow and applicable data, etc.
<Indoor control P.C. board (At shipment)>
<In HEAT operation>
Jumper wire setup
HEAT
shift value
J801
J802
×
×
¡
×
¡
×
¡
¡
¡
: With Jumper wire
×
: Cut Jumper wire
<In 8°C HEAT operation> (–ND model only)
Jumper wire setup
HEAT
shift value
J803
J804
×
×
¡
×
¡
×
¡
¡
¡
: With Jumper wire
×
: Cut Jumper wire
ManualsBase.com
Jumper wire
J801
J802
J803
J804
–2
+4
+2
← At shipment
0
–2
+4
+2
← At shipment
0
– 45 –
Description
1. Purpose
When the difference between the set
temp. of the remote controller and the
room temp. is wide due to the installation
condition, etc, the set temp. is corrected.
(HEAT operation only)
2. Description
The set temp. received from the remote
controller is corrected. The correct value
from –2°C to +4°C is changed by the
jumper wire on P.C. board of the indoor
microcomputer.