7.1.5. The appliance must be installed on fire resistant walls - brick-
built, concrete (with ceramic plating or without it).
7.1.6.It is acceptable to install the appliance on slow burning walls in
condition if the wall is isolated by a zinc-coated steel sheet 0,8...1 mm
thick on a sheet of basalt felt woolen board 3...5 mm. The wall isolation
must come out of the dimensions of the appliance's casing not less than
for 100 mm on every side (scheme 8).
The distance from the side surfaces of the appliance to the slow
burning walls with no usage of isolation must be not less than 250 mm. If
this distance is reduced to 150 mm the installation of heat insulation is
necessary (covering the walls with a zinc-coated steel sheet on a sheet
of heat insulation material).
When installing the appliance on fire resistant walls the isolation
device is not required.
7.1.7. It is prohibited to install the appliance on wooden walls;
plastered walls with a wooden base, on the walls covered with highly
flammable materials.
7.1.8. It is prohibited to install the appliance above a heat source or
open fire.
7.1.9. The place and height of installation of the appliance must provide the fulfillment of the requirements stated in
p. 7.7 of this manual. Herewith it is recommended to install the appliance on such height that the glory-hole would be at the
customer's eye level or as close to it as possible.
Also in order to effect maintenance service at the appliance's installation it is necessary to keep the following spacings:
The distance from the side surface of the appliance to the side wall must be not less than 150 m;
Free space by the inlet into the appliance's front surface must be not less than 600 mm.
7.1.10. Scheme of the appliance's installation (putting it into operation) is shown on scheme 9. It is recommended to
connect the appliance at first to the water supply pipeline, to fill the appliance's system with water and then connect it to the
gas supply pipeline.
Sink

7.2. Mounting the appliance

7.2.1. Before mounting the appliance it is recommended to remove the casing, for this it is necessary to do the following:
а)
To remove the knobs 1 and 2 (see scheme 1, 2), pulling them toward yourself;
б)
to screw out two casing fixation screws on the appliance's bottom part (see scheme 12, 14);
в)
to disconnect the wires, connecting the display with the electronic control block and the water temperature sen-
sor;
г)
to pull the casing's bottom part towards yourself, move it upwards and remove from the appliance;
If the appliance's casing or rear wall is covered with a protective polythene film, the protective film must be removed
before the appliance's installation. Also it is necessary to remove stickers with warning or advertising information from the
casing's front surface (if there are any)
Cold water inlet
Water tap
Gas outlet pipe
Cold water outlet
Scheme 9. The appliance's installation scheme
Scheme 8. Installing the appliance on
Cold water
stop valve
Cold water inlet
Gas pipeline stop
Valve
Gas inlet
Water filter
slow burning walls
Shower device
Water tap
Cold water inlet
Bath