Label - Honeywell Cloud Link 4G Modem User Manual

Table of Contents

Advertisement

Conditions for safe use
The Cloud Link 4G Modem is available with battery pack 51203165-100 which is comprised of a
single cell and a Y connector. A second battery pack (same model) may be connected to this con-
nector to create a 2 cell parallel pack. If a second pack is to be added to an existing pack, the
user shall ensure that both packs are new and unused. The single battery pack or the assembly
of two battery packs shall only be replaced in a non-hazardous area. The connection of more
than 2 battery packs may pose a serious hazard.
None of the battery packs shall be recharged under any circumstances.
The battery packs shall not be replaced in a hazardous area.
The Cloud Link 4G Modem battery packs shall be housed within an enclosure providing a min-
imum ingress protection level of IP 20.
The SIM card connection shall only be used with SIM cards. The SIM card may be connected or
disconnected only in a non-hazardous area or when the device has been de-energized.
All connections into the Cloud Link 4G Modem shall be sourced from Class 2 circuits.
This device shall be installed in a suitable end use enclosure providing a degree of protection
acceptable to the local authority having jurisdiction.
Non-Incendive when Installed As Per Drawing 40-6114

2.2 Label

Honeywell
2016
Figure 2.1 -
Cloud Link 4G Modem Label
2 Safety
2.2   Label
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents