WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK
INTRODUCTION
Congratulations on your purchase of the BAR899HG Wireless
Weather Station with In-Out Thermo-Hygrometer and RF
Clock. This unit is an all-in-one weather forecasting device
which has multiple weather-related functions.
In addition to indoor temperature and humidity, by means of
wireless remote thermo-hygro sensor it can simultaneously
monitor temperatures and humidities in up to 3 remote
locations. The unit will show temperature and humidity
trends as well as record maximum and minimum temperature
and humidity readings.
As part of the weather forecasting function, the unit has a
built-in barometer that displays atmospheric pressure. Using
kinetic-movement graphic illustrations the unit displays
atmospheric pressure trends and displays forecasts as
sunny, partly cloudy, cloudy, rainy and snowy.
This unit is also a Radio Frequency (RF) controlled clock. It
can automatically synchronize its current time and date
WIRELESS WEATHER STATION
MODEL : BAR899HG
USER'S MANUAL
1
when it is brought within an approximate 1500-km radius of
the radio signal DCF77 generated from Frankfurt, Germany.
Other features of BAR899HG include daily crescendo alarm
and Pre-alarm function with an eight-minute snooze function.
No wire installation is required between the main and remote
units as this unit operates at 433 MHz.

Advertisement

loading
Need help?

Need help?

Do you have a question about the BAR899HG and is the answer not in the manual?

Questions and answers

Summary of Contents for Eschenbach BAR899HG

  • Page 1 1500-km radius of INTRODUCTION the radio signal DCF77 generated from Frankfurt, Germany. Congratulations on your purchase of the BAR899HG Wireless Other features of BAR899HG include daily crescendo alarm Weather Station with In-Out Thermo-Hygrometer and RF and Pre-alarm function with an eight-minute snooze function.
  • Page 2 B. CONTROL BUTTONS - FRONT PANEL FEATURES : MAIN UNIT B1 & B2. UP [ ] & DOWN [ ] BUTTONS A. LCD DISPLAY - Increase or decrease in the value of a setting A1. WEATHER FORECAST WINDOW respectively. - Graphically illustrates a weather forecast B3.
  • Page 3 B4. [ MEM ] BUTTON - Displays minimum and maximum temperature and humidity readings, and erases memory data B5. [ CHANNEL ] BUTTON - Displays the temperature and humidity readings of the indoor or remote sensor S N O O Z E B6.
  • Page 4 C4. [ °C / °F ] SLIDE SWITCH - Selects between Centigrade (°C ) or Fahrenheit (°F) T h e r m o - H y g r o S e n s o r temperature unit display C5. [ RESET ] BUTTON Resets the unit by returning all settings to their default values FEATURES : REMOTE...
  • Page 5 BEFORE YOU BEGIN - BATTERY INSTALLATION: MAIN UNIT INSTALLING THE TABLE STAND Remove the battery compartment cover. Before operation, plug the detachable table stand into the display unit as shown. 2. Insert four (4) pieces of UM-3 or "AA" size batteries in accordance with the polarities shown.
  • Page 6 SETTING THE CLOCK AND CALENDAR MANUALLY ABOUT RADIO RECEPTION 1. Press and hold [ MODE ] button for three seconds. The BAR899HG is designed to automatically synchronize its 12-hr value will flash. Use the [ ] or [ ] buttons to...
  • Page 7 2. Press [ MODE ] button again, the hour will flash. Use the SETTING THE ALARM ] or [ ] button to enter the hours. Holding down either the up or down position will increase or decrease To set the Alarm: the value rapidly.
  • Page 8 To stop the alarm sound, press any button (expect [ MEM ] 2. Press and hold the [ ] button for 3 seconds to set the & [ CHANNEL ] buttons). operating time interval for this pre-alarm function. Use the [ ] or [ ] button to select from the 4 time-intervals: If the [ SNOOZE ] button is pressed, the snooze function...
  • Page 9 To clear the memory, press [ MEM ] and hold for three CHECKING INDOOR AND REMOTE seconds. The maximum and minimum recorded readings will TEMPERATURES & HUMIDITIES be erased. Subsequently, if you press [ MEM ] after the memory has been erased, the maximum and minimum To display the indoor and outdoor temperature and humidity readings will have the same values as the current ones.
  • Page 10 cover the next 12 to 24 hours. It may not necessarily ATMOSPHERIC PRESSURE reflect the current situation. The atmospheric pressure arrow shows whether the 3. The "Sunny" icon, as it applies to night time, implies clear atmospheric pressure is increasing, remaining stable, or weather.
  • Page 11 HOW TO CHECK HOW TO WALL MOUNT OR USE THE THE BAROMETRIC PRESSURE TABLE STAND (REMOTE UNIT) The current and historical barometric pressure is shown on As for the remote unit, it has a wall-mount hole and a removable the atmospheric pressure window. stand.
  • Page 12 Wall-Mount: Table-Stand: MAINTENANCE Gently plug in the table stand When handled properly, this unit is engineered to give you as shown: years of satisfactory service. Here are a few product care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth.
  • Page 13 Relative Humidity measurement SPECIFICATIONS Measuring Range : 25 to 95%RH at 25°C (77°F) Main unit Humidity Resolution : 1% RH Indoor Temperature measurement Barometric Pressure measurement Proposed operating range : -5.0°C to +50.0°C Pressure measuring range : 795 to 1050mb / hPa (23.0°F to 122.0°F) (23.48 to 31.01 inHg) Temperature resolution...
  • Page 14 Additional information: CAUTION The product is therefore conform with the Low Voltage Directive 73/23/EC, — The content of this manual is subject to change the EMC Directive 89/336/EC and R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking. without further notice.