Work Area And Equipment Set Up - RIDGID NaviTrack Operator's Manual

Seesnake cs10 10 watt pipe and cable line transmitter
Hide thumbs Also See for NaviTrack:
Table of Contents

Advertisement

Jack for Inductive Clamp
Battery Compartment
Figure 3 – Back View
Icon Legend
Table 2
NaviTrack Line Transmitter Icons
Icon
Variable Current Power ‑ (See section
on Variable Current Power in this Oper-
WATT
ator's Manual for more information)
Battery Status ‑ Hold Power Key down
for two seconds to check battery status
Inductive Mode ‑ Press frequency key
for two seconds to turn ON
External Power 12 – 15 VDC
6 – English
TM
DC Power Jack
Definition
High Voltage Present
Power ON and OFF
Caution
Inductive Clamp
Pre-Operation Inspection
WARNING
Before each use, inspect the NaviTrack Line Transmitter
and correct any problems to reduce the risk of serious
injury from electrical shock or other causes and prevent
machine damage.
1� Confirm that the power is OFF, that leads and any exter‑
nal power and cords are disconnected, and that the bat‑
tery is removed� Inspect the cords, cables, and connec‑
tors for damage or modification�
2� Clean any dirt, oil, or other contamination from the Navi‑
Track Line Transmitter to aid in inspection and to pre‑
vent the unit from slipping from your grip during trans‑
port or use�
3� Inspect the NaviTrack Line Transmitter for any broken,
worn, missing, misaligned or binding parts, or any other
condition which might prevent safe, normal operation�
4� Inspect any other equipment being used per its instruc‑
tions to make sure it is in good, usable condition�
5� If any problems are found, do not use the equipment
until the problems are corrected�

Work Area and Equipment Set Up

WARNING
Set up the NaviTrack Line Transmitter and work area in
accordance with these procedures to reduce the risk of
injury from electrical shock, fire, and other causes and to
prevent damage to the NaviTrack Line Transmitter.
1� Check work area for the following:
• Adequate lighting�
• Flammable liquids, vapors, or dust that may ignite�
If present, do not work in area until sources have
been identified and corrected� The NaviTrack Line
Transmitter is not explosion proof� Electrical con‑
nections can cause sparks�
• Clear, level, stable, dry place for operator�
• Clear path to electrical outlet that does not con‑
tain any potential sources of damage for the power
cord when using external power�