Checking The Version Number - Roland SH-201 Service Notes

Hide thumbs Also See for SH-201:
Table of Contents

Advertisement

May 2006
Checking the Version
Number
1.
Hold down the [TAP] button at the lower left of SH-201, and turn on the
power.
Lighting and turning off of each button of [PRESET], [USER], BANK [A]–
[D] and NUMBER [1]–[8] indicate the version.
PRESET/USER indicates the integral place, BANK indicate the first
decimal place and NUMBER indicates the second decimal place.
(Example )Ver. 1.03
[PRESET] in PREST/USER lights
All LEDs in BANK [A]–[D] light
Only [3] in NUMBER lights
* For examples of version indication, refer to 0. Test Mode Top Page (p. 17),
too.
Users Data Save and Load
Use the "SH-201 Librarian" software in PC to save and load user's data.
Refer to the documents attached the software about detail informations except
the following.
Required Items
• PC installed SH-201 Editor/Librarian (Windows/Mac)
• USB driver for SH-201
• USB cable
* SH-201 Editor/Librarian and USB driver for SH-201 are in the attached CD-
ROM (#04451501).
14
[1.**]
[*.0*]
[*.*3]
Procedure of Save/Load
1.
Start up the "SH-201 Librarian" software program on PC.
On Windows, choose Start -> All Programs -> SH-201 Editor -> SH-201
Library.
On Mac, choose Applications (Roland) -> SH-201 Librarian.
2.
In condition that PC is connected to the SH-201 with a USB cable, open
"Setting for MIDI Device" in the "Setting" menu and select SH-201 for
INPUT and OUTPUT.
3.
Activate the "Main" window of Librarian, click [READ] on the screen. (<-
Never click the wrong button. )
32 patches of USER will be backed up.
4.
Press Ctrl + N (or Command + N on Mac) to open the new "Untitled"
window.
* It's impossible to save contents of "Main" window to files directly.
5.
After activating the "Main" window, press Ctrl + A (or Command + A on
Mac) to select all patches in the Main window.
6.
Press Ctrl + C (or Command + C on Mac), copy all patches.
7.
Activate the "Untitled" window and click the line of "End of ..." to select
it.
8.
Press Ctrl + V (or Command + V on Mac) to paste all patches to the
"Untitled" window.
9.
Click "Save" in the "File" menu.
The file of "***.shl" are backup files which have been saved.
To write the data back into the SH-201 synthesizer, open the backup file by
double-clicking it, paste the data into the Main window using the opposite
procedure as when saving it, and click [WRITE] to write the data back into the
SH-201.
Method of Factory Reset
1.
While holding down the [PRESET] and [USER] button, turn on the
power.
[WRITE] and [CANCEL] will blink.
2.
When you press [WRITE], factory reset will be executed. If you want to
cancel the factory reset, press [CANCEL].
Method of System Update
If the System Updater is released, update the system program through USB
from PC.
Composition of System Update
Files
When you uncompress the supplied update file, SMF data with names similar
to the example shown below will appear. The last file number is p00032, but
the number of files will be less than thirty-two (in the example below there are
thirteen files).
p00001.mid
p00002.mid
p00003.mid
:
p00012.mid
p00032.mid
SH-201/SH-201C