WARNING ∙∙∙∙∙∙·················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙····∙∙∙·∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙······......···......... 3
ABOUT BLOOD PRESSURE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙··························∙∙∙·∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙······∙∙∙··· 4
1. What is blood pressure? ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙····∙∙............ 4
2. What makes my blood pressure change? ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····∙∙∙.........∙∙∙∙∙∙···4
3. What is considered to be as a normal blood pressure? ∙∙∙∙·············∙∙∙·········∙∙∙∙∙∙∙∙∙·······∙∙∙∙∙∙...·· 4
4. Why do I have to check blood pressure at home? ∙∙∙∙∙∙∙∙∙·∙∙∙∙∙∙····∙∙∙··············...···...···...... 5
5. What is the benefit of the data transmissible blood pressure monitor use? ··········...... 5
INTRODUCTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙·················································.........····... 7
WORD DEFINITION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····················∙∙∙∙∙∙∙·············∙∙∙∙································............ 9
NOTE TO USER ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·············∙∙∙∙∙∙∙∙∙∙∙∙∙∙···············∙∙∙∙·····································......... 10
CLASSIFICATION & COMPLIANCE WITH STANDARD ∙∙∙∙∙∙∙∙∙∙∙∙∙∙··································... 10
SAFETY PRECAUTIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙···············∙····················...............11
SAFETY SYMBOLS ∙∙∙∙······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···············∙∙∙∙······························............ 12
PART NAMES & FUNCTIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙················∙∙∙∙∙∙∙∙∙∙∙∙∙···················∙∙∙∙∙∙∙∙··········......... 13
1. Main unit and accessories∙∙∙∙∙∙∙∙∙∙∙∙∙∙················∙∙∙∙∙∙·····························...·······............ 13
2. Symbols in LCD indicator ∙∙∙∙∙∙∙∙∙∙∙∙∙∙···············∙∙∙∙∙∙∙········································............14
PRECAUTIONS FOR MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙····················∙∙∙∙∙····························......... 15
BATTERY INSERTION/REPLACEMENT···············∙∙············································............18
1. How to insert the batteries ∙∙∙∙∙∙∙∙∙∙∙∙∙·················································...········............18
2. Replacement of the batteries ∙∙∙∙∙∙∙∙∙∙∙∙∙∙······················∙∙∙∙∙∙∙····························............18
CONNECTING OF AC ADAPTER ........................................................................... 19
SETTING THE DATE AND TIME ∙∙∙∙∙∙∙∙∙∙∙∙∙∙················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·································......... 19
1. Entering the mode to set date and time ·············∙∙∙∙∙∙∙∙∙∙∙∙∙∙····················...∙∙∙∙∙∙∙............19
2. Setting up ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·····················∙∙∙∙∙............ ...19
SOUND ON/OFF AND VOLUME CONTROL ∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·····················∙∙∙∙∙∙∙∙...... 20
DATA TRANSMISSION∙∙∙∙···········∙∙∙∙∙∙∙∙∙∙∙∙∙∙······················∙∙∙∙·························.................. 21
MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙···········∙∙∙∙∙∙∙∙∙∙∙∙∙∙····················∙······························..................23
1. Wrapping the cuff ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙··············∙∙····················............... 23
2. Correct measuring posture ∙∙∙∙∙∙∙∙∙∙∙∙∙∙····················∙∙∙∙···································............ 24
3. Measuring method ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·············∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙·················............... 24
4. Memorizing ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···········································............... 26
MAINTENANCE AND STORAGE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙·················∙∙∙∙∙∙∙······.........28
1. Maintaining & 2. Cleaning ∙∙∙∙∙∙∙∙∙∙∙∙∙∙······················∙∙∙∙·······························............... 28
TROUBLE SHOOTING ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙············......... 30
1.Against errors ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·····················∙∙∙............... 30
2.Against trouble ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·····················∙∙∙.................. 31
WARRANTY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·················∙∙∙∙∙·······························································......... 32
1. Manufacturer's limited warranty ∙∙∙∙∙∙∙∙∙∙∙∙∙∙···················································............ 32
2. Warranty steps ∙∙∙∙∙∙∙∙∙∙·····················∙∙∙∙∙∙∙∙∙∙∙∙············································............... 32
3. Where applying for solving problem ∙∙∙∙∙∙∙∙∙∙∙∙∙∙······················∙∙∙∙∙····················............ 33
SPECIFICATION ∙∙∙∙∙∙∙∙∙∙∙∙∙············∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙······························......... 34
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECHO-FT and is the answer not in the manual?

Questions and answers

Summary of Contents for Jawon ECHO-FT

  • Page 1 TABLE OF CONTENTS WARNING ∙∙∙∙∙∙·················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙····∙∙∙·∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙······……···……… 3 ABOUT BLOOD PRESSURE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙··························∙∙∙·∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙······∙∙∙··· 4 1. What is blood pressure? ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙····∙∙………… 4 2. What makes my blood pressure change? ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····∙∙∙………∙∙∙∙∙∙···4 3. What is considered to be as a normal blood pressure? ∙∙∙∙·············∙∙∙·········∙∙∙∙∙∙∙∙∙·······∙∙∙∙∙∙…·· 4 4. Why do I have to check blood pressure at home? ∙∙∙∙∙∙∙∙∙·∙∙∙∙∙∙····∙∙∙··············…···…···…… 5 5.
  • Page 2: Warning

    WARNING We highly appreciate you choose this JAWON product. Those who will use this blood pressure monitor are strongly advised to read this manual thoroughly and understand all instructions and warnings before using it. Information in this manual is made for informational purpose and this manual and product are not meant to be a substitute for the advice provided by your own physician or other medical professional.
  • Page 3: About Blood Pressure

    ABOUT BLOOD PRESSURE 1. What is blood pressure? Blood pressure refers to the force or pressure exerted on the artery vessel when blood flows through them. In order to allow the blood to supply nutrition and oxygen to every organ and corner of the body, a certain level of pressure is necessary and it comes from the each time the heart beats or contracts.
  • Page 4: Why Do I Have To Check Blood Pressure At Home

    Without going to a hospital, you can get physician’s advice with data transmissible blood pressure monitor. ECHO-FT is a Home to Hospital bi-directional networking blood pressure monitor that you can transmit saved data from the device to your personal computer through interface then send your physician them. Your physician will read those to find health problems and give proper advice you.
  • Page 5 Also it let your physician optimize the treatment program corresponding your circadian rhythm of blood pressure. Therefore, it is important to take regular daily monitoring and keep clear records. ECHO-FT is a time and cost saving healthcare networking instrument.
  • Page 6: Introduction

    18 and over, in a home care environment. ECHO-FT is designed to enable a person who suspects some trouble with blood pressure to check it at home.
  • Page 7 the third person’s help. Especially it is useful for the elderly person. Memory feature It has 64 reading memory capacity recorded monitoring date and time supported Built-in calendar and clock which are input them automatically to each reading. Accuracy Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or Automated Sphygmomanometers.
  • Page 8: Word Definition

    WORD DEFINITIONS To ensure safe operation and durable performance stability, it is essential that you fully understand the functions, operation and maintenance instructions by reading this manual carefully before using the unit. Particular attention must be paid to all warnings, cautions and notes incorporated herein.
  • Page 9: Note To User

    • Please keep this manual together with the appliance since it is compiled to provide the maximal convenience to those who use this device • Defective unit or accessories that is shipped off from customer to Jawon medical Co. or its authorized dealer for service must be packed in the safe way and the replacement carton.
  • Page 10: Classification & Compliance With Standard

    Classification and Compliance with Standards Model ECHO-FT manufactured by Jawon medical is classified as; ECHO-FT is specified as Class 2 type BF unit under the standard of IEC60601-1 (Safety of Medical Electrical Equipment). Internally powered equipment (Battery : 4 × LR6-AA)
  • Page 12: Safety Precautions

    SAFETY PRECAUTIONS ECHO-FT is designed and manufactured in deep consideration for user’s and operators’ safety and completing reliability of the unit based International Standards for medical equipment. The following precautions must be observed for additional safety ; 1. User must not touch or handle the inner side the system at anytime. It may cause an electrical shock and flame out.
  • Page 13: Safety Symbols

    11. Do not inflate the arm cuff without it being wrapped on the arm. 12. The battery liquid may leak and damage the main unit. Please observe the following points. When you are not going to use the unit for an extended period of time (approximately three months or more), remove the batteries.
  • Page 14: Part Names & Functions

    PART NAMES & FUNCTIONS 1. Main unit and accessories Button : Power ON/OFF, automatic start, enter to sound and volume mode : Memory view, sound off and volume control button : Button to transmit data : Button to enter to the mode to set date and time : Number up button to set date and time USB cable : To use data transmission refer to owners’...
  • Page 15: Symbols In Lcd Indicator

    2. SYMBOLS IN LCD INDICATOR ▲ Pressurization : Displays during inflation ▼ Exhausting : Displays during deflation DATE (10-01) TIME (12 : 00) : month-day hour : minute ♥ : Starts flash when purse is detected : Displays when the batteries need to be changed : Memory indicator : Displays when sound is ON : Indicates noise or movement sensed...
  • Page 16 PREPARATION FOR MEASUREMENT Exercise or any kind of activity may affect Urinating may elevate blood pressure. blood pressure. Rest about 5 minutes Start monitor a few minutes after urination. before monitoring. Lack of sleep or constipation causes the Cold weather causes the blood pressure to blood pressure to rise.
  • Page 17 PREPARATION FOR MEASUREMENT To compare the results, choose the Continuous monitoring causes arm readings got under the same condition. congested and inaccurate readings. Allow (monitoring site, position, time etc.) 3~5 minutes interval between measurements. Take off thick coat, sweater or tight-fit When you roll up your sleeve, ensure it clothes from the monitoring arm.
  • Page 18 PREPARATION FOR MEASUREMENT Do not place on other parts of the body Do not pull it out by force. except the arm. Control the level of the chair and desk to enable your monitoring arm to place at the same level as your heart. When monitoring arm is higher than your When monitoring arm is lower than your heart level, the blood pressure will be...
  • Page 19: Battery Insertion/Replacement

    BATTERY INSERTION / REPLACEMENT 1. How to install the batteries ① Pull the battery cover and open it. ② Insert four AA type batteries to match polarities as shown below. ③ Cover the lid of battery case 2. Replacement of the Batteries ①...
  • Page 20: Connecting Of Ac Adapter

    CONNECTING OF AC ADAPTER Connect the AC adapter between unit and wall outlet SETTING DATE AND TIME • Sequence is Year→Month→Day→Hour→Minute. 1. Entering the mode to set date and time. ① After change batteries the mode appears on LCD automatically. ②...
  • Page 21: Setting The Date And Time

    ③ After setting the month, press [CLOCK] button once again. The day indicator, the second two numbers in upper LCD line, will flash. Set it as same way. Its range is 01 to 31. ④ After setting the day, press [CLOCK] button again. The hour indicator, the third two numbers in upper LCD line, will flash.
  • Page 22: Data Transmission

    DATA TRANSMISSION 1.How to transmit monitoring data to your PC ECHO-FT blood pressure monitor is a Home to Hospital bi-directional networking instrument. You can reserve memorized data on your personal computer then send them to your physician. If you monitor your blood pressure periodically and...
  • Page 23 ② Connect USB cable to a computer and a port of ECHO- FT in order to transmit saved data. ③ Press only one time of [ ] button of ECHO-FT. ④ Press a [ ] button to transmit to a computer.
  • Page 24: Measurement

    MEASUREMENT Remove thick or tight-fit clothes from your upper arm. Sit on a chair with your feet flat on the floor and place your arm on a table so that the cuff can position as same level as your heart. 1.
  • Page 25: Correct Measuring Posture

    2. Correct measuring posture ① Please place your arm with the palm facing up on the table. When the table is too low for your arm to position the heart level, adjust the level off with a cushion, towel or a similar material. ②...
  • Page 26 Then [▲] symbol remains on LCD panel coinciding with a start of pressurization. At this time the number to show the inflated cuff pressure will increase rapidly as a normal process and the cuff will tighten as air enters in it. The value of pressurizing is determined automatically.
  • Page 27: Memorizing

    Even if you forget to press the I/O button, the power will be automatically turned off after 1 minutes. 4. Memorizing ECHO-FT has 64 reading memory capacities. When memorized readings are retrieved, they are displayed with monitoring date and time respectively. The reading detected noise or movement during measurement accompanies [ 1) Storing the readings The readings are stored automatically when the monitoring is completed.
  • Page 28 LCD and the number ‘01’ appears in the memory number displaying part. ③ When the [ ] button is pressed again the second latest reading will be displayed on LCD with the memory number ‘02’. ④ Further pressing of the [ ] button, the data will be displayed respectively in reverse order from the latest one to oldest one with...
  • Page 29: Maintenance And Storage

    MAINTENANCE AND STORAGE 1.Maintaining Avoid exposure to dust, direct sunlight, If this unit is not being used for a long humidity and extreme changes in period of time, please remove the temperature. batteries. Do not drop the unit. Do not disassemble the main body or the cuff.
  • Page 30 Do not fold or bend the cuff forcibly. Do not operate the unit without wrap the cuff around your arm. Note Do not immerse the unit in water. The device exposed to foreign material and exceptional environment need to be check whether the device is functioning properly and safely before using 2.
  • Page 31: Trouble Shooting

    TROUBLE SHOOTING 1. Against Error ERROR CAUSE SOLUTION Err 0 * When inflation level is not * Please set higher inflation sufficient. Level. * When air hose is not * Check if there is any connected well. ‘CAUSE’. * When air leaks from the cuff. * After settle it, monitor * When battery power is low.
  • Page 32: Against Trouble

    TROUBLE SHOOTING 2. Against trouble SYMPTOM CAUSE COUNTERMEASURE The battery power is low. Replace all four “AA” type (When batteries are exhausted batteries at the same time. completely, the mark does not Before change, transmit the appear on the LCD any more.) data to your computer first.
  • Page 33: Warranty

    WARRANTY 1. Manufacturer’s limited warranty The warranty and remedy provided herein are exclusive and in lieu of all other express warranties and unless stated herein, any statements or representations made by any other person or entity are void. Neither the manufacturer, distributor nor their affiliates shall be liable for any loss, inconvenience, injury, or damage including direct, special, incidental, or consequential damages resulting from the use or inability to use this product, whether arising out of any breach of this warranty or any other legal theory.
  • Page 34: Where Applying For Solving Problem

    Manufacturer’s control. 3. Where applying for solving problem Should you be dissatisfied with the service you received from your retailer, please write JAWON MEDICAL CO.,LTD. • Seoul office Tel : *82-2-587-4056 Fax : *82-2-588-1937 • Factory...
  • Page 35: Specification

    * This manual cannot do whole or a part reproduction without notice without written consent of JAWON MEDICAL according to copyright act. * JAWON MEDICAL does not have responsibility about a misprint and do not take the responsibility on the results about which do indication in manual, or did not...

Table of Contents