AXYS ® Intellivox ADC Installation Manual REFERENCE TO EC STATEMENT OF CONFORMITY This document confirms that this product manufactured USER’S NOTICE AND DISCLAIMER: by Duran Audio bears the CE label and meets the No part of this manual including the software described in...
AXYS ® Intellivox ADC Installation Manual 1. IMPORTANT SAFETY INSTRUCTIONS This symbol is intended to alert you to the 8) Do not install near any heat sources such as radiators, presence of uninsulated dangerous voltages heat registers, stoves, or other apparatus (including within the product's enclosure that may be of amplifiers) that produce heat.
AXYS ® Intellivox ADC Installation Manual WHAT’S IN THE PACKAGING In addition to the loudspeaker itself, each unit is packed with the following items: • Installation manual (this document) • ADC Datasheet • Box containing: ITEM Mounting brackets Speaker mounting...
• Unless specified otherwise by the sound system designer, application, it is likely that fire-resistant (pyro) cable will be the Intellivox ADC Model V90 should be installed at a required; local regulations covering these requirements position exactly perpendicular to the listening plane should always be checked and followed.
The vertical position of the acoustic centre of the Model V90 is towards the top of the unit, as indicated by the yellow sticker (see fig.3). The horizontal position is on the vertical centre line.
Acoustic centre reference point for H90 The arrangement of drivers in the H90 differs from the V90; for this reason, a different set of measurements needs to be accurately made. For the H90, the critical aspects of the mounting position are that the horizontal...
Page 10
Dimensions of the bracket are shown in Fig.5.1. The standard brackets allow mounting of the Intellivox fig.5.2 - ADC Model V90 on a straight wall or on a curved surface Direction of rotation when using optional (e.g., a pillar) with a gap of 25 mm (1.0”) between the swivel brackets with rear of the enclosure and the wall.
(0.45”). 2. Mark and drill the holes (8 mm) for the wall plugs. For the V90 use the two holes with the slots running vertically as fig.7 - Connector cover location reference. For H-90 use the slotted hole in the centre of the bracket as reference.
Note that this does not apply to the integral load system, lower powers are available from a 70 V line system. ® monitoring of the AXYS PB400/800 Industry Amplifiers; if The table below summarises the output powers: these amplifiers are being used, the Earth terminal does not need to be connected for surveillance purposes.
Option 1. After making the connections and setting the equalisation (EQ) adjustment at the signal processing stage, power tapping, the front grille may be replaced. Do not or within the power amplifier (as with the AXYS ® PB-400 and replace the protective foam! Align the four locating spigots PB-800 amplifiers).
The fuse is a standard 20 mm ® The AXYS PB-400 and PB-800 amplifiers include a suitable diameter 1 A anti-surge type. Only replace this with a pilot-tone generator;...
AXYS ® Intellivox ADC Installation Manual 4. APPENDICES OPTIONAL ACCESSORIES Listed below are some optional accessories which may be required for a particular installation. DESCRIPTION ORDER CODE Intellivox wall bracket, 25 mm 802225 (2pcs); 802226 (3pcs) Intellivox wall bracket, 35 mm 802235 (2pcs);...
Page 16
IS A REGISTERED TRADE MARK OF DURAN AUDIO BV Koxkampseweg 10, 5301 KK Zaltbommel, The Netherlands. tel. +31 418 515583 fax. +31 418 518077 http://www.duran-audio.com Info@duran-audio.com...