Ravelli Pompeii Owners & Installation Manual

Ravelli Pompeii Owners & Installation Manual

Wood pellet boiler
Table of Contents

Advertisement

Quick Links

economical
leading design
clean air approved
Pompeii Wood Pellet Boiler
Owners & Installation Manual
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION, AND USE OF THIS WOOD PELLET BOILER.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY,
OR EVEN DEATH.
Contact your local building or fire official about restrictions and installation requirement in your area.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pompeii and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ravelli Pompeii

  • Page 1 Pompeii Wood Pellet Boiler Owners & Installation Manual PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION, AND USE OF THIS WOOD PELLET BOILER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
  • Page 2 If you are a not a registered pellet re installer, and do not have legitimate access to the necessary passwords to install and program Pompeii Wood Pellet Boiler, you MUST NOT install or attempt to install this  e. Wood Pellet Boiler requires technical programming...
  • Page 3: Table Of Contents

    Owner’s Section - Table of Contents Introduction ....................3 ....................... 3 Safety Warnings & Recommendations ..........4 Installation ........................4 Deciding where to locate your wood pellet burning boiler ........5 Ash ..........................5 Clinkering ........................5 Filling Fuel Hopper ....................... 5 Flammable Liquids .......................
  • Page 4 Operating your Pellet Fire..............13 Preliminary Operation ....................13 Description of Handheld Set ................... Handheld Touch Radio Initialization ............... 14 Description of the Display ..................15 Time and Date Settings .................... 15 Loading the Auger ....................16 Setting Ambient and Boiler Water Temp ..............17 Turning the Device on ....................
  • Page 5: Introduction

    This manual is designed for both the technician and the home owner. Please read this entire manual before installing or operating your Ravelli Pompeii Freestanding Wood Pellet Burning Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
  • Page 6: Safety Warnings & Recommendations

    Safety Warnings & Recommendations Pellet quality is important, please read the following: Your pellet heater has been designed to burn ¼” (6mm) diameter wood pellets, manufactured to the AS/NZS 4014.6 only. DO NOT use this appliance as an incinerator. DO NOT use unsuitable and non recommended fuels, including liquid fuels, as this will void any warranties stated in the manual.
  • Page 7: Deciding Where To Locate Your Wood Pellet Burning Boiler

    This will assist the appliance to perform to the level required. the Pompeii heats space by convecting air across the top of the unit, the heater should face the majority of the area to be heated.
  • Page 8: Flammable Liquids

    Flammable Liquids Never use gasoline, gasoline – type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen” up a fire in the stove. Keep all such liquids well away from the stove while it is use. Operating Instructions The stove is completely automated and will self-regulate the ignition phase, two levels of power and the switching off phase, guaranteeing safe functioning.
  • Page 9: What Are Wood Pellets

    The pellets must be transported and stored in a dry place. They swell on contact with any moisture and cannot be used. They must always be protected from moisutre, both during transport and in storage. Ravelli recommends using a pellet with a diameter of 6 mm for the stove. The Components of the Stove...
  • Page 10: Pellet Combustion

    Pellet Combustion Combustion is simply a chemical reaction between combustible and carburant. The result of this reaction is the heat. The three elements that are required for combustion are: -Combustible (pellet) -Carburant (oxygen available in the air) -Ignition (electrical resistance for ignition) PELLET To achieve combustion, the combustible and the carburant must be available in the correct proportions.
  • Page 11: Maintenance And Cleaning

    Maintenance and Cleaning Before carrying out any maintenance, take the following precautions: Make sure that the stove has been turned off, and that the general power supply has been disconnected • (Ensure that the plug is disconnected from the socket, thus avoiding accidental electric shocks). •...
  • Page 12: Cleaning The Ash Drawer

    Cleaning the Ashes Draw The ashes drawer must be cleaned every days, depending on the length of time the stove is used, and the type of pellet used. To access the drawer, open the door (see figure extract ashes drawer (see figure N.B.: The operation must be...
  • Page 13: Access To The Inspection Hatches For Cleaning The Smoke

    Access to the inspection hatches for cleaning the smoke Remove the side panels and release the two screws that secure the hatches to the body of the pellet stove. Clean the inside using a drum type vacuum cleaner. INSPECTION HATCH GASKET INSPECTION HATCH GASKET...
  • Page 14: How To Clean The Tubulators

    How to Clean the Tubulators Pull to clean exchanger tube bundle...
  • Page 15: Operating Your Pellet Fire

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.22 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.22 Preliminary Operations Preliminary Operations Wiring Preliminary Operations Wiring power cord of the stove. What to check befor turning on the stove power cord of the stove.
  • Page 16: Handheld Touch Radio Initialization

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.23 Handheld touch radio initialization Handheld touch radio initialization In order to operate correctly, the handheld set should be interfaced with the electronic board installed inside the stove. For this FIRST INSTALLATION? PRESS THE KEY RADIO ADJ ON THE STOVE...
  • Page 17: Description Of The Display

    When you replace the batteries, you do not have to run the initialization procedure of the handheld set. In this case, when on display appears the message “FIRST INSTALLATION ?”, select NO Description of the display Description of the display The display of the handheld set is described below (in stand-by mode): Vers.
  • Page 18: Loading The Auger

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.25 Time and date setting Time and date setting Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.25 Below are given the steps for accessing the relative menu. Time and date setting MENU USER...
  • Page 19: Setting Ambient And Boiler Water Temp

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.26 Setting ambient and boiler water temperature: Setting ambient and boiler water temperature: Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Set the two values following the indications given in the chapter “Description of the display” Pag.26 Turning the device on Setting ambient and boiler water temperature:...
  • Page 20: Operating Phases Of The Stove

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.27 Operating phases of the appliance Operating phases of the appliance Modulation During the work phases, the appliance is aimed at reaching the room/water temperature set by the user; when one of these conditions is met, the stove switches to MODULE WORK phase, in which fuel consumption is minimised. Should it be necessary to measure the room temperature using an external thermostat (optional), the latter must be connected to the dedicated connector to the rear of the stove;...
  • Page 21 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.28 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO The first setting allows you to enable the COMFORT CLIMA function which is aimed at checking that the temperature set for room/ Pag.28 water is maintained at the set value for a maximum period of X minutes (SHUTDOWN DELAY: 5 MIN) before switching to before The first setting allows you to enable the COMFORT CLIMA function which is aimed at checking that the temperature set for room/...
  • Page 22 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.29 Orario di accensione impostabile Orario di spegnimento impostabile Giorno della settimana con programma attivo Numero programma “crono” (1-2-3-4) Settaggio della temperatura ambiente Settaggio della temperatura acqua caldaia By pressing the Increment key you can change each value and, at step 3, enable the days of the week; By pressing the Increment key you can change each value and, at step 3, enable the days of the week;...
  • Page 23 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.30 Stove State Below are given the steps for accessing the relative menu starting from Stand-By mode. MENU USER USER POWER SETTING STOVE STATE USER CHRONOTHERMOSTAT COMFROT CLIMA MANUFACTURER’S SCREW LOADING SETTING TECHNICIAN SET AIR-PELLET...
  • Page 24 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.31 Settings > Enable thermostat DATE-TIME DATE-TIME ENABLE THERMOSTAT ENABLE EXT. T ENABLE EXT. T SEASON SEASON CONTRAST CONTRAST FW VERSION FW VERSION LANGUAGE LANGUAGE ADJUST ADJUST Press the key Press the key Press the “enter”...
  • Page 25 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.32 Settings > Language To access the next setting, follow the steps given above or simply remove and replace the batteries. The device resets and prompts you again to select the language you want to set. Settings >...
  • Page 26 Below is shown the new display mode and the function of every icon for every layout, to change the various settings. If the type of system designed requires controlling the 3-way valve (diagram 1 and 3), it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer. Layout 1 (DHW Boiler + heating control) The following layout can be used when you have a boiler that is not equipped with plate heat exchanger and you intend to buy a puffer that should be connected to the circuit to produce hot domestic water.
  • Page 27 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.34 Layout 2 (storage puffer management) In this type of circuit, the storage puffer is managed by the stove due to a contact or immersion probe (optional) connected to the back of the stove.
  • Page 28 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.35 Stove phase general layout FASE DESCRIZIONE The stove is in the switch off phase and the cooling phase has not been completed yet. FINAL CLEANING The heater pre-heating phase has started and the pellets start to fall into the grate. SWITCH ON The pellets ignite and take advantage of the heat in the intake air that passes through the WAITING FOR FLAME...
  • Page 29 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.36 PHASE DESCRIPTION The stove is off When the switch-on request from ECO-STOP mode coincides with an automatic switch-off WAIT FOR PELLETS condition (from the TIMER), the stove turns on ensuring total cleaning of the brazier before OUT OF switching to FINAL CLEANING.
  • Page 30: Alarms

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.37 6.9.1 Alarms (table with reference codes) Alarms (table with reference codes) TITLE REASON SOLUTION TRIAL. - No voltage during work phase - Press the switch off key and switch on the stove again AL 01 BLACK OUT...
  • Page 31 Vers. 01 del 07/04/15 Pag.38 EACH ALARM CAUSES THE IMMEDIATE SWITCHING OFF OF THE STOVE. PRESS THE SWITCH-ON BUTTON TO RESET THE ALARM. BEFORE SWITCHING ON THE STOVE, MAKE SURE THE SIGNAL HAS BEEN REMOVED AND (UNLIKE MODELS EQUIPPED WITH AUTOMATIC CLEANER) THAT THE BRAZIER IS PROPERLY CLEANED TO ENSURE CORRECT RESTART.
  • Page 32 7. Maintenance Record DATE WORK CARRIED OUT SIGNATURE Page 16...
  • Page 33: Warranty Information

    Auger Motor manufacture. After installation, if any covered components Circuit Board, manufactured by Ravelli are found to be defective in decal & mounting materials or workmanship during the applicable warranty bracket period, Pellet...
  • Page 34: Warranty Exclusions

    EXCEPT TO THE operation, abuse, misuse, continued operation with EXTENT PROVIDED BY LAW, Pellet Solution damaged, corroded or failed components, accident, Ravelli MAKES NO EXPRESS WARRANTIES OTHER or improperly/incorrectly performed repairs; (5) THAN THE WARRANTY SPECIFIED HEREIN. environmental conditions, inadequate ventilation,...
  • Page 35: Proof Of Purchase/Warranty

    9. Proof of Purchase/Warranty Use this page to note down the details of your wood pellet fi re purchase, and attach the receipt and any other documents/ business cards from the retailer that sold you the fi re. Name of Store where Pellet fi re was purchased: ....................... Date of Purchase: .......................
  • Page 36 Installation Section Table of Contents Dimensions Ravelli Pompeii ............... Deciding where to locate your wood pellet burning stove: ........36 Clearances to Combustibles – Ravelli Pompeii Freestanding ......36 Exhaust and Fresh Air Intake Locations ..............36 Installation ....................37 Dimensions –...
  • Page 37: Dimensions Ravelli Pompeii

    V - Hz 220 – 50 Tank capacity Space Heating The data shown above are indicative and not binding. Ravelli reserves the right to make any for the purpose of improving the performances of the product. FLOW 3/4 RETURN 3/4...
  • Page 38: Deciding Where To Locate Your Wood Pellet Burning Stove

    Due to the operating nature of the Pompeii pellet stove, where opening the door causes a loss of vacuum and the fire will shut down completely, meaning the likelihood of any hot embers or burning fuel escaping from the combustion chamber is extremely minimal.
  • Page 39: Installation

    Specifications were correct at time of printing but may alter, and those detailed below should be used as a guide only. Refer to the Installation and Operation Manual supplied with every Ravelli Pellet Fire or if in doubt, consult your Pellet Retailer.
  • Page 40: Minimum Clearance To Combustibles

    Location of a power source • The Pompeii has a convection fan which blows air across the top of the unit in the direction that the fire faces, for optimum performance this location should be in a large room centrally located.
  • Page 41: Internal Standard Flue Kit (50)

    Internal Standard Flue Kit (50) Internal Standard Flue Kit Pompeii 50S Pom This flue kit may be used in new and replacement applications in rooms with stud height of 2.4m. The overall height of the flue is 3.6m. The visible flue is finished in black and the ceiling plate is white.
  • Page 42: External Standard Flue Kit (51)

    The overall height of the flue is 3.6m. All visible flue has a galvanised finish, and can be powdercoated on request. Kit is supplied in a carton. 600mm from roof penetration Each 51 External Standard Flue Kit Pompeii contains:- Part No Description Quantity Galvanised outer liner ø100mm x 900mm long...
  • Page 43: Seismic Restraint

    Pompeii requires a power source to function. This is standard mains feed 240v plug - if this is unavailable in close proximity, a grounded extension lead may be used.
  • Page 44: How To Mount The Side Panels

    2.12 How to mount the side panels...
  • Page 45: Seismic Restraint Locations

    2.13 Seismic Restraint Locations SEISMIC RESTRAINT LOCATION SEISMIC RESTRAINT LOCATION...
  • Page 46: Hydraulic Installation

    READ THE NEXT CHAPTER. RAVELLI DENIES ALL LIABILITIES FOR DAMAGES TO PEOPLE OR PROPERTY ARISING FROM MALFUNCTIONS DUE TO FAILURE TO COMPLY WITH THIS WARNING Pellet Fire Solutions, along with Ravelli, only recommend the use of a closed loop system when installing the Pompeii Pellet Boiler. Safety devices for closed tank system According to the standard UNI 10412-2 (2006) in force in Italy, closed systems must be equipped with: •...
  • Page 47: Examples Of Hydraulic Installation

    Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO 2.15 Examples of hydraulic installation Pag.20 Examples of hydraulic installation Direct circuit to the system Pellet boiler Distribution heating collectors Radiators Thermometer Manometer Area 1 Anti-condensation valve Non-return valve Direct distribution unit Thermostatic distribution unit Radiating panel ( oor heating) Shut-o valves...
  • Page 48 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.21 Pellet boiler Motorized three-way valve with spring return Non-return valve Expansion vessel Distribution heating collectors Gas boiler Direct distribution unit Solar pump unit Radiators Thermostatic distribution unit Solar collector Thermometer Radiating panel ( oor heating) Thermostatic mixing valve...
  • Page 49: Installation Data Sheet

    Installation Data Sheet Name of Owner: Name of Dealer: ________________________________ ________________________________ Address: Address: ________________________________ ________________________________ ________________________________ ________________________________ ________________________________ ________________________________ ________________________________ ________________________________ Phone: Phone: ________________________________ ________________________________ Model: __________________________ Name of Installer: ________________________________ Serial Number: ____________________ Address: Date of Purchase: __________ (dd/mm/yy) ________________________________ Date of Installation: _________ ________________________________...
  • Page 50: Maintenance Record

    Maintenance Record DATE WORK CARRIED OUT SIGNATURE...
  • Page 51: Producer Statement And Warranty Registration Form

    PRODUCER REGISTRATION FORM This form must be completed and returned for every installation to qualify for warranty. Post to: P O Box 11-245, Sockburn, Christchurch Email to: info@pelletfiresolutions.co.nz Customer Details: Customer Name: Postal Address: Installation Address: Phone Number Cell Phone Email Address Declaration by Owner: I hereby certify the above particulars are true and correct.

Table of Contents