7.8 TOOL HOLDER CABINET MOVING:
CHECK AND REPLACEMENT
: 1,5h
: End wrenches of 13,17,19 and 30mm, Allen
wrench of 4,5 and 6mm, rubber hammer ,
green loctite.
: The defective cabinet tool holder moving
may cause the following malfunctions:
1. Incomplete mount dismount tool rotation.
TO CHECK THE CABINET TOOL HOLDER:
Turn on the machine.
Move the tool holder arm 'till end of the stroke.
Check if the cabinet is worn (Fig.270 and
271).
Fig.270
Fig.271
TO REPLACE THE CABINET TOOL HOLDER:
Remove the lifting tool holder cylinder from
the tool holder assy
Remove the tool holder assy from the saddle
7.3.
Remove the set screw #1 from ring nut
(Fig.272).
6.18.
Fig.272
Remove the ring nut #2 by using the same
specific wrench used to remove the robotic
rotor ring nut ( 7.6 Fig.253).
Replace the cabinet with the new one by
greasing accurately the new bushing.
Tighten the ring nut #2.
IMPORTANT!
THE THREADED RING NUT HOLE MUST
MATCH WITH THAT ONE ON THE HOLDER
ARM THREAD LIKE THAT ONE OF
FIG.259.
Tighten the set screw #1 by using green
loctite and verify that it moves free.
Remove the screws shown in Fig.273.
Fig.273
Replace the shims (Fig.275).
Tighten FIRMLY the screw of Fig.273.
Mount the tool holder assy on the saddle
7.3.
Mount the lifting tool holder cylinder
Adjust the bolts of Fig. 274.
115
7.6
6.18.
Service Manual 04/2010 Rev.B