Advertisement

Quick Links

Processautomatic Ratex AB
PA105 & PA106 Manual
PA105
&
PA106
Pre-Amplifier
BY
PROCESSAUTOMATIC
Author: Stefan Björnmalm
Issue: 4
Approval: Per-Johan Åkerlund
Effective: 2017-04-25
PRODUCT MANUAL FOR:
PA-105 & PA106 Pre-Amplifier.
By: Processautomatic©
Page 1 of 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PA105 and is the answer not in the manual?

Questions and answers

Summary of Contents for Processautomatic PA105

  • Page 1 Processautomatic Ratex AB Author: Stefan Björnmalm Issue: 4 Approval: Per-Johan Åkerlund Effective: 2017-04-25 PA105 & PA106 Manual PA105 & PA106 Pre-Amplifier PROCESSAUTOMATIC PRODUCT MANUAL FOR: PA-105 & PA106 Pre-Amplifier. By: Processautomatic© Page 1 of 9...
  • Page 2: Table Of Contents

    PRODUCT DESCRIPTION: ............................5 PA105-Pre-Amplifier:..............................5 PA106-Pre-Amplifier:..............................5 Connection Diagram: ............................... 6 Terminal Connection diagram for PA105 & PA106: ....................6 Connecting the PA105 Pre-Amplifier: ........................7 Connecting the PA106 Pre-Amplifier: ........................8 Other references: ............................... 9 Warranty: ................................... 9...
  • Page 3: Contact Information

    Exceeding recommended supply voltage can cause bodily harm or death. 3.1 Handle the product with care. Dropping the product or other miss use causing impact on the PA105 or PA106 can cause product failure. 3.2 Change Intervals: It is recommended to replace the PA105 &...
  • Page 4: Back-Up System

    5 THE PURPOSE OF THIS MANUAL: This manual is designed to guide any and all users of Process Automatic PA105 & 106 Pre- Amplifier to safe and proper handling. It is only thru safe and proper handling that the end user will get the most out of this product.
  • Page 5: Product Description

    The maximum current load is 20mA. These are appropriate for source inputs or pulse inputs. In opposite to the PA105, the out-put signal is always closed – until a signal from the pick-up sensor comes. The output signal will then have the same amplitude as the supply voltage.
  • Page 6: Connection Diagram

    4. Connect the (-) negative supply cables copper wire to terminal 2. 5. Connect the (+) positive supply cables copper wire to terminal 1. NOTE: The diagram illustrates a PA105 Pre-Amplifier – However, the terminal on the PA105 Pre-Amplifier & the PA106 Pre-Amplifier are identical.
  • Page 7: Connecting The Pa105 Pre-Amplifier

    9.2 Connecting the PA105 Pre-Amplifier:  Red cable: Supply voltage, V+ = 5-30V  Green cable: Output open collector, max load 500mA  Blue Cable: 0V, Supply and signal.  Temperature Range: - 40 to +70C  Enclosure Protection: IP65 standard ...
  • Page 8: Connecting The Pa106 Pre-Amplifier

    9.3 Connecting the PA106 Pre-Amplifier:  Red cable: Supply voltage, V+ = 5-30V  Green cable: Output source, amplitude = V+, max load 20mA  Blue Cable: 0V, Supply and signal.  Temperature Range: - 40 to +70C  Enclosure Protection: IP65 standard ...
  • Page 9: 10 Other References

    10 Other references: Please also refer to the Product data sheet. Both the product data sheet and the latest version of this manual can always be found for download on the Processautomatic web site www.processautomatic.com 11 Warranty: This product has a 1-year (one year) factory warranty. The warranty only covers the product being used under the recommendations in this manual.