SECTION 5: INSTALLATION
Club Chair V2
THE FOLLOWING TECHNICAL DIAGRAMS SHOULD BE GIVEN TO YOUR ENGINEERS,
ARCHITECTS, DESIGNERS, ELECTRICIANS & PLUMBERS.
Failure to comply with federal, state, or local codes and ordinances could result in the
voiding of product warranty as well as potential injury and flooding. A licensed plumber
should make all utility connections. All plumbing connections must conform to local
codes. Water temperature/pressure should not exceed local regulations.
The following footprint establishes the MINIMUM recommendations.
• Note: The floor has to be capable of supporting the expected load - minimum 200 lbs.
• Note: If your chair has back tilt, a minimum of 12" should be between the wall and the back of the
chair when upright which will allow the chair to tilt back to its farthest point.
• Note: The soaking tub will not have the hydrotherapy jets installed. Plumbing and electrical
connections are the same.
Wall
12"
76.5"
66.25"
38.5"
50.5"
wall to end of tub
wall to center of drain
15.75"
center of drain