  • Page 3: Table Of Contents

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus INDEX 1 - INTRODUCTION ..........................9 1.1 GENERAL GUIDELINES ..........................9 1.2 SAFETY GUIDELINES ............................. 9 1.3 RECOMMENDATIONS ............................. 9 1.4 GENERAL GUIDELINES ..........................9 1.5 TRANSPORTATION AND STORAGE ......................10 1.6 GUIDELINES FOR CORRECT DISPOSAL OF THE PRODUCT ..............
  • Page 4 Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 9 - CLEANING AND MAINTENANCE ...................... 32 9.1 FOREWORD ..............................32 9.2 CLEANING AND MAINTAINING THE APPLIANCE ..................32 9.3 AIR FILTER ..............................34 9.4 CHARGING THE BATTERY OF THE THERMOCOMFORT HANDHELD CONTROL (optional) ....34 9.5 BATTERY REPLACEMENT FOR INFRARED REMOTE CONTROL ............
  • Page 5 Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus EU Declaration of Conformity (DoC) Dichiarazione di Conformità UE (DoC) Company name: THERMOROSSI S.P.A. Azienda: Postal address: VIA GRUMOLO, N° 4 Indirizzo: Postcode and city: 36011 ARSIERO (VI) Codice postale e città:...
  • Page 6 Name, registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11( 5): THERMOROSSI S.P.A. Via Grumolo, n° 4 36011 Arsiero (Vicenza) Sistema o sistemi di valutazione e verifica della costanza della prestazione del prodotto da...
  • Page 7 Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus Prestazione dichiarata / Declared performance Specifica tecnica armonizzata: EN 14785:2006 Harmonized technical specification: Caratteristiche Essenziali Prestazione / Performance Essential characteristics Sicurezza antincendio / Fire safety Reazione al fuoco / Reaction to fire Minime distanze / Minimum distances (mm): posteriore / rear = 200 Distanza da materiali combustibili...
  • Page 8 Name, registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11( 5): THERMOROSSI S.P.A. Via Grumolo, n° 4 36011 Arsiero (Vicenza) Sistema o sistemi di valutazione e verifica della costanza della prestazione del prodotto da...
  • Page 9 Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus Prestazione dichiarata / Declared performance Specifica tecnica armonizzata: EN 14785:2006 Harmonized technical specification: Caratteristiche Essenziali Prestazione / Performance Essential characteristics Sicurezza antincendio / Fire safety Reazione al fuoco / Reaction to fire Minime distanze / Minimum distances (mm): posteriore / rear = 200 Distanza da materiali combustibili...
  • Page 10: Introduction

    Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 11: Transportation And Storage

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus ATTENTION: before any use, make sure the burner is thoroughly clean and check that the sliding door of the combustion chamber is properly closed and air-tight. ATTENTION: during operation, the sliding door of the combustion chamber must always remain properly closed. It is strictly forbidden to open it while the appliance is in operation.
  • Page 12: Technical Characteristics

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 2 – TECHNICAL CHARACTERISTICS BELLAVISTA™ R BELLAVISTA™ R M.U. SILENT PLUS Height 1,493 1,493 Depth 670 – 971 670 – 971 Width Empty weight Firebox power (Min. / Max.)* 3.89 / 10.52 4.43 / 12.36 Rated power Min.
  • Page 13: General Description

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance. 3.2 THE PELLET The appliance is fuelled by pellets, that is, cylinders of compressed sawdust;...
  • Page 14: Installation

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 4 - INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which the appliance is to be installed must withstand the combined weight of the appliance and the pellets contained in the tank.
  • Page 15: Installation Of Glass On Base

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 4.3 INSTALLATION OF GLASS ON BASE Gently extract the glass (B) from the packaging (C) Silicone-coat the surface of the base (A) using single-component, acetic silicone suitable for high temperatures (minimum 200°C, maximum 300°C).
  • Page 16: Relocation Of The Control Panel

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 4.4 RELOCATION OF THE CONTROL PANEL The product is supplied with the control panel on the right side; if needed, the control panel can be moved to the left side of the appliance.
  • Page 17: Installation Of Airbox 3 Ventilation Kit (Optional)

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 4.5 INSTALLATION OF AIRBOX 3 VENTILATION KIT (OPTIONAL) Airbox 3 ventilation kit can be installed on the appliance. By introducing this optional, the appliance will become Plus, therefore ventilated and ductable.
  • Page 18: Handle

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus C- dx C - sx 5) Unscrew the 4 knobs (A) and remove the cast-iron top 6) Insert deflectors (C – sx/LH) and (C – dx/RH). Open (B), pulling it upward. the sliding door of the combustion chamber (for this operation, refer to the specific chapter) and secure the two deflectors with 4 screws (E) and 4 washers (D).
  • Page 19: Opening The Sliding Door Of The Combustion Chamber

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 4.7 OPENING THE SLIDING DOOR OF THE COMBUSTION CHAMBER To open and close the sliding door of the combustion chamber, release the fastening hook (B) by acting on the suitable handle. In the same way, release fastening hook (C) also by acting on the suitable handle.
  • Page 20: Description Of The Controls

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the glass of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
  • Page 21: Description Of The Power Panel

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus DATE/TIME This button is used to set the day of the week, the hour and minutes. (see para. 5.3) CHRONO This button is used to set the programmed on and off sequences. (see para. 5.4) LEVEL Is used to change the rotation speed of the smoke suction unit.
  • Page 22: Date/Time: Setting The Date And Time

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 5.3 DATE/TIME: SETTING THE DATE AND TIME The appliance must be energised and the I/0 switch in position “I". The current date and time can be set using the DATE/TIME function. To set the current time and date proceed as follows: 1) Press the Menu Button once to view the following screen: 2) After a few seconds the following screen will appear on the display:...
  • Page 23 Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus The following screen will appear: At this point if no further programming is required for that day go to point 5-A. If, on the other hand, you wish to program a second ON/OFF cycle for that day go to point 5-B. 5-A) Press the Menu Button to exit the screen, in order to enable you to program the times for the ON/OFF cycles for the other days of the week.
  • Page 24: Level: Operating Level Setting

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus ATTENTION: In the event of a programmed cycle on always ensure that the brazier is clean. Failure to clean the brazier can reduce and/or affect the life of the spark plug as it would be subjected to high temperatures due to poor cooling.
  • Page 25: Thermocomfort: Connection With The Handheld Control (Optional)

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus After a few seconds the following screen will appear on the display: To change the operating level, hold down a Scroll Button while simultaneously pressing the other Scroll Button. To set the desired level simply press the Menu Button several times until the initial screen will appear on the display.
  • Page 26: Operation Of The Handheld Control Thermocomfort (Optional)

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 6 - OPERATION OF THE HANDHELD CONTROL THERMOCOMFORT (OPTIONAL) The Thermocomfort handheld control is the instrument that allows you to optimise both consumption and functions. If set in AUTO mode, the handheld control detects the room temperature where it is located and automatically manages the modulation of the combustion power and the ventilation power (only in the PLUS version) of the appliance according to the target temperature set by the user in the handheld control.
  • Page 27: Use Of The Handheld Control

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 6.2 USE OF THE HANDHELD CONTROL The Thermocomfort handheld control can be used with 4 different operating programs: • MANUAL • AUTO 5 • AUTO 3 • ECONOMY To change an operating program hold down the DOWN arrow on the handheld control until the set program begins to flash.
  • Page 28: Transmission Codes Settings

    Devices or parts returned for replacement become the property of Thermorossi. S.p.A. The presence of any irregular black-blue lines on the display, also present when de-energised and/or battery flat or missing, indicate that the glass screen of the display is damaged following a fall or impact: in this case the breakage is not covered by the guarantee.
  • Page 29: Use Of The Appliance

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 7 – USE OF THE APPLIANCE 7.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
  • Page 30: Channelling

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 7.5 CHANNELLING It is possible to choose to distribute the flow partly to the front and partly to the channelling at the rear (only in the PLUS version). Flow regulation takes place by acting on the suitable levers as indicated in the following figure: ATTENTION: The temperature of the channelling levers is very hot while the stove is operating, so take care not to touch them.
  • Page 31: Room Temperature Thermostat / Chronothermostat (Optional)

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 8 – ROOM TEMPERATURE THERMOSTAT / CHRONOTHERMOSTAT (optional) The appliance can be connected to an additional room temperature thermostat or to an additional chronothermostat: This operation must be exclusively performed by qualified professional staff, as set forth by Decree no. 37 of 22nd January 2008 and applicable laws on the subject.
  • Page 32: Operating With The Additional Room Temperature Thermostat (Not Supplied)

    ATTENTION: Use N.O. (normally open) contacts for the connection to the chronothermostat. ATTENTION: In the event of connections to the chronothermostat Thermorossi S.p.a. shall not be held responsible for the appliance not starting up, smoke leaks or breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
  • Page 33: Installation, Use And Maintenance Guide Bellavista™ R Silent - Bellavista™ R Plus

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 9 - CLEANING AND MAINTENANCE 9.1 FOREWORD Before beginning any maintenance operation ensure that the appliance is switched OFF and disconnected from the electric power socket. Your appliance, being a pellet-fuelled appliance, requires regular general controls and cleaning.
  • Page 34 Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus ATTENTION: after cleaning it is mandatory to carefully check that the sliding door of the combustion chamber is firmly closed and airtight. ATTENTION: the generator, the smoke channel and flue outlet must be cleaned in accordance with the specifications described above and use of inflammable products is strictly forbidden: using inflammable products can create dangerous situations.
  • Page 35: Air Filter

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus FIGURE - 5 FIGURE - 6 FIGURE - 8 FIGURE - 7 9.3 AIR FILTER Your appliance is fitted with an air filter (only in the PLUS version); a practical device that prevents the circulation of dust particles that are always present in domestic environments.
  • Page 36: Battery Replacement For Infrared Remote Control

    The batteries are guaranteed for 6 months. Attention: Use only the battery charger provided by Thermorossi. The use of any other type of battery charger will invalidate the product warranty. Flat batteries must be removed and safely disposed of. Use rechargeable AAA 1.2 V min.
  • Page 37: Smoke Discharge Tube And Ventilation Of The Rooms

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 10 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 10.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 38: Flue Outlet / Flue System Components

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 10.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Every chimney must have minimum number components as laid down by standard UNI EN 1443 which are also indicated in the figure on the left. Wall outlets, that is outlets installed on the outer front wall without the use of a chimney/flue outlet /flue pipe to convey the combustion products to the roof, are strictly...
  • Page 39: Controls Prior To Installing The Appliance

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 10.3.3 CONTROLS PRIOR TO INSTALLING THE APPLIANCE The user must possess a certificate of conformance for the flue outlet (Ministerial Decree 22 January 2008, no. 37). The flue outlet must be built in compliance with UNI 10683. The smoke exhaust shown in the following figures is the best solution to ensure the discharge of smoke even when the fan is not operational, such as for example if there is an electrical power failure.
  • Page 40: Alarms

    ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
  • Page 41: Electrical Wiring

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 12 - ELECTRICAL WIRING Motoriduttore caricamento pellet Spia Verde 121110 Morsettiera CN 5 Morsettiera CN 7 Pressostato Motore Pellet Power Termostato Riarmo Ventialtore ambiente Aspiratore fumi Resistenza accensione Fus.
  • Page 42: Information For The Skilled Technician

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 13 - INFORMATION FOR THE SKILLED TECHNICIAN 13.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 43: Troubleshooting Causes-Solution

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 13.3 TROUBLESHOOTING CAUSES-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE FOLLOWING ALARM IS SHOWN ON THE DISPLAY “NO PELLET”...
  • Page 44 Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus PROBLEM POSSIBLE CAUSE SOLUTION ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE OPERATES THE APPLIANCE NEEDS TO RUN FOR MORE HOURS AT A INTERMITTENTLY HIGHER POWER; SET A HIGHER ROOM TEMPERATURE THE APPLIANCE SHOULD OPERATE FOR MORE TIME AND THE ROOM IS TOO LARGE, THE WALLS ARE COLD THE APPLIANCE DOES...
  • Page 45: Spare Parts

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 14 – SPARE PARTS 14.1 SPARE PARTS 1/6 70020937 Copertura vano 70020951 Legenda 70020984 Copertura vano Compartment cover Sportellino completo Complete door retro Rear panel 70020948 70022596 Sportellino completo 70022797 Retro...
  • Page 46: Spare Parts 3/6

    Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus 14.3 SPARE PARTS 3/6 70020810 70020811 Guarnizione 60010185 Legenda 70010402 Guarnizione Gasket Maniglia Handle Estrattore fumi Smoke extractor 60010185 Guarnizione Gasket 60011428 Termocoppia J Thermocouple J Pannellino completo Complete panel 70011497 70018484...
  • Page 47: Spare Parts 5/6

    Manuale d'installazione, uso e manutenzione guide BellaVista™ R Silent - BellaVista™ R Plus 70022797 70022831 14.5 SPARE PARTS 5/6 Guarnizione tenuta porta / 2,8m 70022797 70022706 Legenda 70022795 Profilo reggivetro Guarnizione tenuta Door tightness gasket porta / 2,8m / 2.8 m Profilo reggivetro Glass supporting profile...
  • Page 48 Installation, use and maintenance guide BellaVista™ R Silent - BellaVista™ R Plus F ire L o v e rs Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Page 47 Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it...

This manual is also suitable for:

Bellavista r plus

Table of Contents