Pacific Sun Metis Hyperion S User Manual page 5

9 channel led aquarium lamp with smt matrix
Hide thumbs Also See for Metis Hyperion S:
Table of Contents

Advertisement

Click Firmware Upgrade – and select the firmware for your type of lamp ( firmware file extension is .bin).
Your lamp's firmware is being updated. When the process is completed, you will see „Firmware updated" displayed in the status
window.
If the error occurs during transmission of the CRC and the firmware will not load properly - lamp will go to safe mode.
The screen appears:
Memory Erased. Upload firmware.
This means that the transmission process is not finished successfully.
To restore full functionality of the lamp you must perform the following steps:
a) Reduce the distance between the lamp and the computer to an absolute minimum - or use an external BlueTooth module.
b) restart the lamp by disconnecting it for a few seconds after the voltage
c) re-run the application, select the correct COM port (do not press on Connect to the lamp!)
d) go to the Service Tab - click Firmware upgrade - and then select the correct firmware for your lamp
At this point, the firmware update process should start - the status bar will show the current progress update.
If you need additional information - please contact our service: