Appendix B : Hard Alarm Output; Figure 102 : Hard Alarm Output - AVE VSI-Pro Max Operation Manual

Pos / cash register interface
Hide thumbs Also See for VSI-Pro Max:
Table of Contents

Advertisement

HARD ALARM OUTPUT
The VSI-Pro provides two open collector transistor alarm outputs to trigger alarming devices. These are Alarm 1 & 2
in the Alarm menu. Upon an Exception, a VSI-Pro can be programmed to trigger a VCR to go to its fastest record
time, have a Quad go full screen, home a switcher, trigger a preprogrammed PTZ, or provide visual or audible
alarms. The VSI-Pro provides two alarm outputs that are rated at 12VDC @ 20mA maximum.
The following are some basic circuit designs to take advantage of the alarm output option of the VSI-Pro.
5 VDC
Internal
To
VSI-Pro
RELAY SPDT
Internal
To
VSI-Pro
VSI-Pro Max POS / Cash Register Interface
470 OHM
LED
Alarm 1 or 2
Output
5 VDC
1N4001
Alarm 1 or 2
Output
Figure 102: Hard Alarm Output
Internal
To
VSI-Pro
Internal
To
VSI-Pro
62
APPENDIX B
12 VDC
1K OHM
LED
Alarm 1 or 2
Output
5 VDC
BUZZER
Alarm 1 or 2
Output

Advertisement