  • Page 2: Specifications

    Water supply must be microbiologically safe. WARNING PROPERTY DAMAGE  In situations where any water leakage could result in damage to property, the complete Schwan Installa- tion should be installed over a Drained Safe Tray, plumbed to an appropriate drain .
  • Page 3 Component Checklist Main Components. Schwan Dispenser Schwan Boiling Tank Dispenser Fitting Kit Dispenser Base and clamp Assembly Base assembly clamping screws Grub screw and Allen Key Dispenser base O-ring Boiler hose clamp Water Supply Fitting Kit 6mm x 600mm food grade nylon tubing.
  • Page 4: Typical Installation Lay Out

    Plumber) Schwan Boiling Tank—————- —— Drained safe tray WARNING In situations where any water leakage could result in damage to property, the complete Schwan installation should be installed over a Drained Safe Tray, plumbed to an appropriate drainage connection.
  • Page 5  The dispenser must be within 600mm of the proposed location of the Schwan under bench boiling tank, and filter system. (Ref Diagrams 11 and 14) DIAGRAM 3 IMPORTANT ...
  • Page 6: Installing The Dispenser

    DIAGRAM 6  Insert base clamp assembly through the 35mm diameter hole, and pull up on “tabs” to draw the clamping plate into position under the bench. DIAGRAM 7 IMPORTANT  Rotate the base assembly to the correct orientation as illustrated so that the dispenser will face the correct way once installed.
  • Page 7 DIAGRAM 11 WARNING In situations where any water leakage could result in damage to property, the complete Schwan Installation should be installed over a Drained Safe Tray, plumbed to an appropriate drain . Max. distance between...
  • Page 8: Connect Water Supply

    DIAGRAM 14 CONNECT WATER SUPPLY Overview of water Diagram 14 shows an overview of the water supply connection to filter. connection including the Pressure Regulator. IMPORTANT Pressure The pressure regulator must be installed upstream (before)  Regulator the tap assembly. Water flow must be in the direction indicated by the arrow ...
  • Page 9 DIAGRAM 18 Turn on water supply  DIAGRAM 19 Check all fittings and tube connections to and from  the tap for water leakage. If any leaks are noted ensure they are repaired  before moving onto the next step. DIAGRAM 20 5 min DIAGRAM 25...
  • Page 10: Check For Leaks

    DIAGRAM 22 CHECK FOR LEAKS Check all fittings and tube connections to and from  the boiling tank for water leakage. (Ref. Diagram 22) If any leaks are noted ensure they are repaired  before moving onto the next step. DIAGRAM 23 CONNECT TO POWER SUPPLY Plug power lead into power supply and switch on...
  • Page 11 If steam and water spurts from the dispenser,  adjust the thermostat dial back one increment to lower the set temperature, and repeat the test sequence to confirm correct setting. YOUR SCHWAN IS NOW READY FOR USE.
  • Page 12: Troubleshooting

     A delay of 2 or 3 seconds is normal especially if your Schwan has not been used in the last hour or so. This is due to the efficient operation of the “expansion tank” within the boiling unit which protects against the risk of hot water dripping from the dispenser.