Titon SR700 Installation Manual

Single room heat recovery ventilation fan unit.single room heat recovery ventilation controller unit
Hide thumbs Also See for SR700:

Advertisement

Quick Links

Product Installation Manual
Single Room Heat Recovery Ventilation Fan Unit
Single Room Heat Recovery Ventilation Controller Unit
EN
SR700 SRHRV Fan
SRC1 Controller
ventilation systems
TP600
TP590

Advertisement

Table of Contents
loading

Summary of Contents for Titon SR700

  • Page 1 SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC1 Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems...
  • Page 2: Warnings, Safety Information And Guidance

    Controller Unit is suitable for 220-240V ~ 50-60Hz single phase with a fuse rating of 3A. 7. Control & communication cable - Titon recommends the use of unshielded CAT5e cable to comply with EMC directives. 8. Control & communication cables should not be placed within 50mm or on the same metal cable tray as any mains lighting or power cables.
  • Page 3: Table Of Contents

    SR700 Fan Unit                                     ...
  • Page 4: Product Information

    The system provides an easily installed and maintainable solution for removing internal condensation and eliminating mould growth within the home. Unlike regular extractor fans that waste 100% of heat that passes through them from the home, the SR700 system will recover up to 94%, based on in house testing, of wasted heat.
  • Page 5: Packaging Contents

    Inspect the units when taking delivery. Check the units for damage and that all accessories have been supplied. SR700 Fan Unit Package supplied with: ƒ SR700 Fan unit x 1; ƒ Product Installation Manual x 1. Any shortages or damage must be immediately reported to the supplier.
  • Page 6: Installation

    Installation Component Diffuser Bezel Wiring Aperture Cover Spring Steel Clip Air Filter Component Heat Cell Fan with Connectors Vent Tube Foam Strip Seal positions (not supplied) Foam Fly Screen External Louvre SRHRV Fan Unit ‑Components...
  • Page 7: Srhrv Fan Unit

    SRHRV Fan Unit Read and observe the guidance & safety notices listed in Warnings, Safety Information and Guidance . The Titon SRHRV Fan unit is designed to be mounted through a wall with a thickness between 305mm & 700mm. ƒ...
  • Page 8: Vent Tube

    Vent Tube fig 1 Outside Area that can be removed. Min Cut Line Inside Inside Outside fig 2 Installation, Cutting & Orientation Prepare Vent Tube. Cut out one of the Wiring Pockets Using a sharp blade, cut out the material highlighted to create an aperture to accommodate the 12v fan connection, fig 1.
  • Page 9: External Louvre

    External Louvre External Louvre, Screw Ports and Sealant Groove Fit three of the Spring Steel Clips to the positions on the External Louvre. Fit External Louvre. Louvre is a push fit. If screw fixing is desired drill out the three screw ports from the inside to the outside of the External Louvre using a Ø4mm drill.
  • Page 10: Internal Bezel

    Internal Bezel Note: Position of serial label to be visible when installed. Internal Bezel Fit the remaining three Spring Steel Clips to the positions on the Internal Bezel. Fit Internal Bezel. Internal Bezel is a push fit into the Vent Tube, when fitting ensure Wiring Aperture is aligned with the Wiring Pocket in the Vent Tube.
  • Page 11: Internal Components

    Internal Components Fit Internal Components Fit the first Ceramic Heat Cell. Slide a Ceramic Heat Cell into the Vent Tube. Ensure the Wire Handle is facing the inside and that the Ceramic Heat Cell is pushed up against the stop in the Vent Tube. Fit the Fan.
  • Page 12: Diffuser

    Diffuser Fit Wiring Cover and Diffuser Connect the Fan Cable. Using the push connector connect the Fan Cable to the Communication Cable, see wiring section for details. Fit the Air Filter, which is held in place by the Wiring Aperture Cover. Fit the Wiring Aperture Cover.
  • Page 13: Wiring

    Wiring Fans Connection Connection of Fan Unit(s) to Controller is to be made with specified communication cable. Up to 3 pairs (six fans) can be connected to the controller by connecting multiple cables to each terminal or by using a separate larger capacity connector. Extract Supply Controller SRC1 FAN 1...
  • Page 14: Src1 Controller Unit

    SRC1 Controller Unit All necessary control components are integrated in this device. The SRC1 Controller is designed to fit into a single flush mounting wall box. Mains External Digital Input Switch (optional) see note Fuse All Pole Isolator L1 N L1 N FAN 1 FAN 2...
  • Page 15: Sensors

    Sensors Extract Supply Controller SRC1 FAN 1 FAN 2 B + - - + S 4 3 2 1 Surface Mount Sensors A B + - Flush Mount Sensors Sensor to controller connection Sensor Options Sensor type Surface mount Flush mount Relative humidity (RH) sensor TP610 TP614...
  • Page 16: Commissioning & Controls

    Decrease Heat Speed Recovery Commissioning & Controls Increase Cross ventilation Cross Speed Ventilation Heat recovery Error Decrease Humidity protection Heat Speed Recovery Reduced speed Nominal Intensive speed Cross ventilation Controller Heat recovery Operation Error The fans can operate either in heat recovery mode (default) or in cross ventilation mode. In heat recovery mode, the fans will change direction periodically.
  • Page 17: Sleep Mode

    Sensor PCB, Encoder Highlighted The type of sensor will be detected automatically. For every type of sensor there are 3 threshold levels. The parameters are Humidity, CO2 and VOC threshold. For humidity only, one of three different sets of thresholds can be selected in the service menu. See below table of thresholds. Function threshold Fan speed Threshold value...
  • Page 18: Service Menu

    Service Menu The Service Menu can be used to configure external sensors and adjust other controller parameters and is based on the buttons and the LEDs. In order to enter the service menu, the two left buttons have to be held for at least five seconds. When in service mode, all three LEDs on the left side (cross ventilation, heat recovery and error) will be activated, either flashing or permanently lighting up.
  • Page 19: Errors

    Number Display Menu FLASH Function of digital input 1=sleep timer (Default) FLASH Fan level off allowed 1=not allowed (Default) 2=allowed FLASH Sensor sensitivity 1=low 2=medium (Default) FLASH 3=high FLASH LED brightness Increase and decrease using UP and DOWN arrows. Fan selection FLASH 1=Fan settings 1 (Default) 2=Fan settings 2...
  • Page 20 MARKETING DIVISION 894 The Crescent, Colchester Business Park,COLCHESTER, CO4 9YQ Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com ©2017 TITON DO 5482 Iss 05...

This manual is also suitable for:

Tp600Src1Tp590