Extract ventilation unit
cme1 q plus;
cme1 q plus with humidity sensor (28 pages)
Summary of Contents for Titon SR700
Page 1
SRC1 Controller TP590 Single Room Heat Recovery Ventilation Controller Unit SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit Product User Manual ventilation systems...
6. The SRC1 Controller Unit is suitable for 220-240V ~ 50-60Hz single phase with a fuse rating of 3A. 7. Control & communication cable - Titon recommends the use of unshielded CAT5e cable to comply with EMC directives. 8. Control & communication cables should not be placed within 50mm or on the same metal cable tray as any mains lighting or power cables.
Page 3
11. The appliance is not suitable for installation to the exterior of the dwelling. 12. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appli- ance in a safe way and understand the hazards involved.
Contents Warnings, Safety Information and Guidance Important Information 2 Product Information Dimensions & Component Identification 6 Controller Operation Introduction 8 Heat Recovery Mode 9...
Unlike regular extractor fans that waste 100% of heat that passes through them from the home, the SR700 system will recover up to 94%, based on in house testing, of wasted heat. When used as part of a whole house system it can...
Packaging Contents Inspect the units when taking delivery. Check the units for damage and that all accessories have been supplied. SRC1 Controller Unit Package supplied with: SRC1 Controller Unit x 1; Product User Manual x 1. Install / Commissioning leaflet x 1. ...
Page 7
SRHRV Fan Unit ‑Components No. Component No. Component Diffuser* Fan with Connectors Bezel Vent Tube Wiring Aperture Cover Foam Strip Seal positions (not supplied) Spring Steel Clip Foam Fly Screen Air Filter External Louvre Heat Cell *Front face may have protective film. If present, please remove.
Controller Operation Increase Cross Speed Ventilation Decrease Heat Speed Recovery Cross ventilation Heat recovery Error Humidity protection Reduced speed Medium speed Intensive speed Controller Introduction The controller has 2 modes of operation, Heat Recovery- which is the default and Cross Ventilation. These are selected via the buttons on the left hand side of the controller.
Heat Recovery Mode In Heat Recovery Mode the Supply and Extract fans change directions at regular intervals, warming the Heat Cell when extracting from the property and recovering the stored heat when supplying air to the property. This is the default operating mode. Cross Ventilation Mode In warm weather when heat recovery is not required Cross Ventilation mode simply supplies air to one side of the property and extracts from the other to create a cooling flow of air.
Sensor Operation If room sensors have been installed these will control the fan level depending on the environmental parameter being measured. If the fan speed is being controlled by the sensor this will be indicated by LEDs 5, 6 or 7 flashing quickly. The up arrow can be used to increase the ventilation rate above the sensor determined level.
Maintenance Cleaning Routine cleaning and filter changes are all that are normally required to keep the SRHRV System working efficiently. Before cleaning ,power down the ventilation system and wait sufficient time for the Fans to stop rotating before starting cleaning. SRHRV Fan Unit Diffuser Remove Diffuser before cleaning with a soft cloth damped with mild soapy water.
Replacement Filters Description Part Number Air Filter G2 XP2010838 Air Filter G3 XP2010311 Foam Fly Screen XP2010320 Replacement filters are available from Titon Sales SRC1 Controller Unit Cleaning Wipe down the exterior with a soft cloth damped with mild soapy water.