FM Marin Gobius 4 Installation Manual

Hide thumbs Also See for Gobius 4:

Advertisement

Quick Links

Document release 5.12, July 2017
Gobius 4 for Waste Holding Tanks, new version 5.0

Installation Guide

Before you begin
1. Please make sure that no part is missing. 3 sensors, 1 panel,
1 control unit, 1 3M cleaning towel, 1 Velcro fastening for the
control unit, cables, 1 extra sensor tape (3M VHB 4932), warranty
statement and installation instruction on how to attach the
sensors.
2. Determine the best places (¼-, ½- and ¾-level) on your tank to
place the sensors and where to place the panel.
3. Determine the best way to safely access electricity from your
battery 12/24 Volts.
Quick installation
Attach the sensors to the tank
Connect all parts
Start Gobius
Calibrate
Test Gobius
Ready
Attaching the sensors to the tank
Start by reading through the
sensors to the tank wall. Please visit www.gobius.se for latest news. There
is also Tank Calculator for making it easier for you to calculate the right
levels to put the sensors on the tank wall.
Connect all parts
1. Decide where to place the Gobius panel. It can for instance be
installed in your head/shower or near your waste holding tank.
You may increase the length of the panel cable up to 50 m with a
standard PC network Cat 5 cable.
2. We suggest that you make a small rectangle hole where you want
to place the cable from the panel to the control unit. The hole
should be at least 4 mm x 22 mm. Please see the enclosed hole
template at page 5.
3. Use the pre-attached 3M adhesive to fasten the panel to the wall.
4. Connect the panel and the sensors to the control unit. Then
connect the cable to the battery. Make sure to connect + and –
correctly to the battery (+ is white/grey marked and – is black),
FM Marin AB
Ljungåsvägen 2
302 91 Halmstad
Sweden
green
document before attaching the
Phone
+46 31-65 01 70
info@gobius.se
www.gobius.se

Advertisement

loading

Summary of Contents for FM Marin Gobius 4

  • Page 1: Installation Guide

    Document release 5.12, July 2017 Gobius 4 for Waste Holding Tanks, new version 5.0 Installation Guide Before you begin 1. Please make sure that no part is missing. 3 sensors, 1 panel, 1 control unit, 1 3M cleaning towel, 1 Velcro fastening for the...
  • Page 2 as also described on the control unit. Please see the illustration at page 5. 5. If you want to connect Gobius to an external display from VDO, Wema, Faria or others, you should use the analogue output on the control unit together with the enclosed black cable. Start Gobius Connect power source cable to the control unit.
  • Page 3 switching on the power from an external source. A function control on lamps and sensors is immediately performed. When the control is done the level is measured and the correct lamp is lit. You turn off Gobius by a quick push on the button or by switching off the current from an external source.
  • Page 4 The electronics of the product are protected from damp. The sensors and the control unit do not resist water. Please contact FM Marin for advise on how to make Gobius waterproof. Furthermore, we recommend that you connect your Gobius via a 500 mA fuse.
  • Page 5 System Illustration Plug from control unit to the panel Attaching sensors to the tank (If you connect the panel cable wrong way the red lamp on the panel will constantly light. It will not damage the product.)
  • Page 6 Indicators in Setup Mode Mark Lamp Lamp Lamp Lamp Duration your Description Yellow Green Blue in seconds choose ● ● ● ● Calibration ○ ● ○ ○ Measurement period 1 minute ○ ● ○ ● Measurement period 5 minutes ○ ●...
  • Page 7 ○ ○ ○ ☼ Tank level 1/4 ○ ○ ○ ☼ Tank level 1/2 ○ ○ ○ ☼ Tank level 3/4 After measuring ○ ○ ○ ● Tank is empty ○ ○ ● ○ Tank level 1/4 ○ ● ○ ○...
  • Page 8: Control Unit

    Electrical specification Supply Voltage: 11 ~ 29 V DC Supply Current: 200 mA max. (Operating), 50 mA max. (Idle) Lamp driver outputs: 29 V DC max, 200 mA max 4-20 mA current loop, 10-190 Ω, 240-33 Ω, 0-5 Volt DC Analogue Instrument outputs: Max.