3. ADJUSTMENTS
To measure the peak-to-peak voltage (Vpp), expand the waveform to 5 s/div. In
the example shown on the previous page, the amplitude is 220 Vpp.
CH
1
2
3
4
CH
1
2
3
4
3.2

Heading Alignment

1. Turn on the power. Locate a target (buoy, etc.) in the bow direction and display it
on the screen at a close range. The heading alignment is correct if the target in
the bow direction is displayed 12 o'clock on the screen. If it is not, go to step 2.
Buoy
2. Read the skewed degree of the target selected at step 1.
3. Press the [MENU] key.
4. Use the [RANGE] control to choose [MENU MODE].
5. Use the [GAIN] control to choose SYSTEM to show the System menu.
**
[MENU MODE]
DIMMER
DISP SELECT
HEADING ADJ
AUTO RETRACT
6. Rotate the [RANGE] control to select HEADING ADJ.
7. Rotate the [GAIN] control to set value so a target directly ahead in bow direction
is displayed at 12 o'clock.
3-2
Typical value of TX output (68 kHz)
Vout +, -
CH
100 Vpp
5
100 Vpp
6
175 Vpp
7
175 Vpp
8
Typical value of TX output (55 kHz)
Vout +, -
CH
140 Vpp
5
140 Vpp
6
240 Vpp
7
240 Vpp
8
Displaying a buoy on the screen
SYSTEM MENU
**
: SONAR
: 10
:
TEMP
:
: OFF
System menu
Vout +, -
CH
240 Vpp
9
240 Vpp
10
240 Vpp
11
240 Vpp
12
Vout +, -
CH
310 Vpp
9
310 Vpp
10
310 Vpp
11
310 Vpp
12
When the target on the screen is
skewed to the right, the transducer
heading is skewed to the left.
(RANGE CTRL: U/D, GAIN CTRL: L/R)
SOUNDER
MARKS
CURRENT
(OFF,
5-16kn)OFF
Vout +, -
175 Vpp
175 Vpp
100 Vpp
100 Vpp
Vout +, -
240 Vpp
240 Vpp
140 Vpp
140 Vpp
SYSTEM