System Installation CAUTION: Do not use systems on untreated well water that is microbiologically unsafe. Do not exceed 125 psi water pressure. Do not exceed 110F water temperature. Do not subject unit to freezing conditions All plumbing must be in compliance with local and state plumbing codes.
Page 3
OVERVIEW • Plumbing connections o Shut off main o Release water pressure o Make pipe connections • Level I valve programming (Initial settings) o Current Time o Current Date • Level II programming (settings made at factory) • Drain line connection •...
Plumbing Connections Be sure to comply with all required plumbing codes. 1. Shut off main water supply to the home. 2. Release water pressure by opening a faucet at the kitchen sink or other location. Important! - Be sure to lubricate the o-rings on the quick connect fittings prior to installation.
Page 5
• Metered for demand regeneration • Ideal for softeners, iron, sulfur, carbon and sediment filters HF 500 • For tanks to 16” (softeners) • For tanks to 10” (filters) • Easy to program • Operational data shown on LED,...
Valve Programming FIRST - UNLOCK VALVE Press and hold for 3 seconds to unlock the valve for programing.
Page 7
2) Set / Save Regen Key Press this key to select a program or to save a setting Up arrow Key Press these keys to go to the HF 500 previous menu Down arrow Key Press these keys to go to the next menu...
Page 8
Level-I Set up Parameters (Required for initial set-up) Level-1 Time – Enter the time of valve set up. Date - Enter today’s date at time of valve set up. Number of People – Enter # of full-time residence (default 4). Water Hardness - Enter grains of hardness (default 20).
Page 9
Making Adjustments – Level I All programing is adjusted using the methods described in the programing method. Setting level I programing Time 1) Press * to enter menu (hour display will be highlighted) 2) Press to enter hour setting (must be flashing to edit) 3) Press to adjust hour 4) Press...
Level-II Programming (Settings have been pre-set at the factory) Level-II These settings have been made at the factory and are held in memory. Level-II settings will not be lost during a power outage. However, if adjustments are desired, follow the directions below.
Page 11
Making Adjustments – Level II All programing is adjusted using the same methods as for Level-I programming. Setting level II programing Backwash 1) Press together to enter menu (5 sec.) 2) Press scroll to backwash setting 3) Press to enter menu (flashing) 4) Press to adjust minutes (flashing) 5) Press...
Page 12
AIR DRAW INSTALLATION Aerus Origins® control valves are highly effective for Iron, Hydrogen Sulfide and Manganese reduction by using our unique “air draw” installation to introduce fresh air to the filter tank for added oxidation. Air draw is not required in many installations (depending on Iron, Sulfur and Manganese concentrations), so testing is advisable.
Connect Drain Line Connect drain line to the valve Slide drain line tube over barbed drain line connection fitting until secured. IMPORTANT Proper backwash is critical for Iron/Sulfur filters Therefore, do not tee-off drain line or use ½” drain tubing longer than 20’. (Use ¾” or 1” drain line for longer runs).
Page 14
System Installation Turn the by-pass valves to the “OFF” position (red valves) pointing “across” the valve as shown. With the faucet still on, open the main water supply valve. Off Position CAUTION: Inspect all plumbing connections. Check for leaks and make repairs as needed...
System Start Up Notice: For initial start-up, the Inlet and Outlet valves on the bypass should be in the closed position. 1) Press and hold to enter Manual Regen Mode (press for 3-5 seconds) 2) Press to enter edit mode (flashing) 3) Press to select immediate (flashing) 4) Press...
Page 16
Start-Up In Backwash 1) Screen will now display “Backwash” and flash “Remaining XX min” 2) You will need to run Backwash cycle until drain line runs clear NOTE: When advancing to another cycle, valve will show “advancing to”. Once the valve is “in”...
Page 17
Fill the Mineral Tank CAUTION: Allow time for glued connections to cure before proceeding. If the mineral tank was not filled, do so at this time following the directions below: With bypass valves in the “OFF” position turn on the main water supply.
Page 18
System Installation Leave the system in backwash for a minimum of ten to fifteen minutes or until the water runs clear. This will flush loose particles and preservatives from the media. REPEAT of the initial backwash cycle may be required should the backwash discharge water does not run “clear”...
Page 19
Ready for Service 1) Slowly open outlet to supply water to the house. 2) Open faucet in the house to remove debris and air to flush system.
Weather Cover (For outdoor installations) WARNING If the water treatment system is to be installed outside, exposed to the weather and/or UV Rays, it is necessary to install a weather cover over the valve. The weather cover will protect the valve from the damaging effects of UV Rays on the LCD Screen and is required to submit a warranty claim.