Thermostat Programs; How To Get To The Thermostat Program Screen; Slow Cooldown Program (Program 1); Fast Cooldown Program (Program 2) - Lopi Foxfire Manual

Table of Contents

Advertisement

Thermostat Programs

This heater comes with three thermostat programs built in. Each program is unique and allows you to modify
your thermostat setting to your preference.

How to Get to the Thermostat Program Screen

Press the Menu Button Until "T-stat Program" appears on the digital readout.
Use the Heat Setting slider on the touch screen to adjust between the three thermostat programs.

Slow Cooldown Program (Program 1)

When the thermostat stops calling for heat (the thermostat is open) the thermostat "steps down" to a lower heat
setting. The heater will stay at this setting for 15 minutes. If the thermostat does not call for heat, the thermostat
will "step down" again to a lower setting (or off). At any time if the thermostat calls for heat (thermostat is closed)
during this cycle, the heater will resume at the HEAT output setting set at the control board.
Heater Set at
6 to 10
Heater Set at
3 to 5
Heater Set at
1 to 2
NOTE: This program is not recommended for areas with little heating requirements (mild climates, small rooms, etc.).

Fast Cooldown Program (Program 2)

When the thermostat stops calling for heat (the thermostat is open) the following happens:
The burn rate decreases to Level 1 (lowest) for 15 minutes. If there is no call for heat during that time the heater
turns off.
If there is a call for heat by the thermostat (the thermostat is closed) at any point during this cool-down period
then the burn rate resumes corresponding with the setting on the control panel.

Low Burn Program (Program 3)

In Thermostat Mode Program 3 when the thermostat stops calling for heat (the thermostat is open) the
following happens:
The burn rate decreases to Level 1 (low) and remains at this level until there is a call for heat by the thermostat
(the thermostat is closed), then resumes corresponding with the setting on the control panel.
© Travis Industries
Operation
T-stat Program
SlowCool
SlowCool
FastCool
Heat Setting
If thermostat calls for heat
(thermostat closed)
Heater runs at setting set on
control panel dial.
If thermostat calls for heat
(thermostat closed)
Heater runs at setting set on
control panel dial.
If thermostat calls for heat
(thermostat closed)
Heater runs at setting set on
control panel dial.
LowBurn
If thermostat stops calling for heat (thermostat open)
Heater goes to 6.
If after 15 minutes thermostat still open, heater goes to 3.
If after 15 minutes thermostat still open, heater goes to 1.
If after 15 minutes thermostat still open, heater turns off.
If thermostat stops calling for heat (thermostat open)
Heater goes to 3.
If after 15 minutes thermostat still open, heater goes to 1.
If after 15 minutes thermostat still open, heater turns off.
If thermostat stops calling for heat (thermostat open)
Heater goes to 1.
If after 15 minutes thermostat still open, heater turns off.
4141007
27
100-01402

Hide quick links: