Inputs
Outputs
Performance
l a r k t e k n i k . c o m
Equalisation
Terminations
Power Requirements
Dimensions
Weight
Options
BS EN ISO 266:1997 Frequency Centres:
The ISO standard frequencies
25 Hz, 31.5 Hz, 40 Hz, 50 Hz, 63 Hz, 80 Hz, 100 Hz, 125 Hz, 160 Hz, 200Hz, 250 Hz, 315 Hz, 400 Hz, 500 Hz, 630 Hz, 800 Hz, 1.00 kHz, 1.25 kHz, 1.60 kHz, 2.00
kHz, 2.50 kHz, 3.15 kHz, 4.00 kHz, 5.00 kHz, 6.30 kHz, 8.00 kHz, 10.0 kHz, 12.5 kHz
Due to a policy of continual improvement, the Klark Teknik Group reserves the right to alter the function or specification at any time without notice.
Two
Type
Impedance (Ohm
)
Max input level
Two
Type
Minimum load impedance
Source impedance
Maximum output level
Frequency response
EQ out
EQ in (flat)
Distortion (THD+N)
Dynamic range
Overload indicator
Gain
30 Bands
Centre Frequencies
Tolerance
Maximum Boost/Cut
High Pass Filter Slope
Low Pass Filter Slope
Notch filter
Audio
Power
Voltage
Consumption
Height
Width
Depth
Nett
Shipping
DN
Electronically balanced (pin 2 hot)
20k
+22dBu
Electronically balanced (pin 2 hot)
600ohms
<60ohms
+22dBu >2k ohm
±0.5dBu, 20Hz-20kHz relative to signal at 1kHz
±0.5dBu
< 0.003% @ 1kHz, +4dBu
>114dB (20Hz-20kHz unweighted),
+20dBu
- infinity to +6dBu
To BS EN ISO 266:1997 25Hz-20kHz, 1/3 octave
±5%
±12dB, ±6dB
12 dB/octave
12 dB/octave
Attenuation >18dB, Q=32
3-pin XLR and 6-pin Phoenix
3-pin IEC
100V-240V a.c.
<60W
133mm (5.25 inch) 3U High
482mm (19 inch)
205mm (8 inch)
5.8kg
7.0kg
Input and output balancing transformer
Hz
370
Operators Manual -
Page 21

Technical specification

±
12dB range

Hide quick links:

Advertisement

Table of Contents
loading