Quest Engineering A3000 Installation, Operation And Maintenance Instructions

Power air mover

Advertisement

Quick Links

Quest Power Air Mover A3000
Installation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
– Read and Save These Instructions –
This manual is provided to acquaint you with
the Quest Power Air Mover A3000 air mover
so that installation, operation and mainte-
nance can proceed successfully. Ultimate
satisfaction depends on the quality of set up
and a thorough understanding of this equip-
ment. The Quest Power Air Mover A3000 is
built around tested engineering principles and
has passed a
thorough inspection for quality of
workmanship and function.
Quest Power Air Mover A3000:
• Less than 2.5 amps
• Automatic hour meter displays site run time
• 20 ft AC cord with cord management
• Units interlock for ease of stacking during
storage and handling
• Weighs 2.5 lbs less than competitive units
• Over 3000 CFM on high
quest
quest
Specifications subject to change without notice.
4201 Lien Rd.
Madison, WI 53704
www.QuestProtect.com
1
Patent 7,331,759
Phone 608-237-8400
Toll-Free 1-866-933-7486
sales@QuestProtect.com
TS-955
11/17 Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Quest Engineering A3000

  • Page 1 – Read and Save These Instructions – – Read and Save These Instructions – This manual is provided to acquaint you with the Quest Power Air Mover A3000 air mover so that installation, operation and mainte- nance can proceed successfully. Ultimate...
  • Page 2: Table Of Contents

    Quest Power Air Mover A3000 Installation, Operation and Maintenance Instructions Table of Contents Quest Power Air Mover A3000 Features ....1 Safety Information ..........3 Intended Application ........4 3. Safety Certifications ..........4 4. Specifications ...........4 Power Requirements .........4 5.1 Recommended Use ........4 5.2 Integrated Cord Wrap .........4 Applications .............5...
  • Page 3: Safety Information

    Quest Power Air Mover A3000 Installation, Operation and Maintenance Instructions 1. Safety Information • Do not operate the unit with a cut or frayed power cord. Replace cord if it becomes damaged. • Do not unplug the unit by pulling on the cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle.
  • Page 4: Intended Application

    Installation, Operation and Maintenance Instructions 2. Intended Application The Quest Power Air Mover A3000 has changed the drying industry by minimizing overall drying time on water restoration jobs. The Quest Power Air Mover A3000 uses patent pending FOCUS Technology to maximize air velocity across floors and along walls for longer distances. By maximizing the air velocity,...
  • Page 5: Quest Power Air Mover A3000 Features

    The Quest Power Air Mover A3000 dries in counter-clockwise and clockwise directions for optimum ease of use. The Quest Power Air Mover A3000 ships with rubber feet on one side of the unit for counter-clockwise drying. When employing clockwise drying (such as the need to dry a door jamb), simply rotate the axial air mover 90° so the FOCUS Technology corner points toward the door jamb...
  • Page 6: Operating Instructions

    Installation, Operation and Maintenance Instructions 7. Operating Instructions The Quest Power Air Mover A3000 as packaged is ready to be put into service. Inspect the unit completely for any shipping damage. Place the unit on the ground. Orient the unit so the desired air flow direction is the same as the arrow indicator sticker in the FOCUS Technology corner on the interior of the unit. Plug the unit into a grounded outlet and select the drying mode shown in Figure 6.
  • Page 7: Replacement Parts And Optional Accessories

    Quest Power Air Mover A3000 Installation, Operation and Maintenance Instructions 10. Replacement Parts and Optional Accessories Contact the factory at 1-866-933-7486 to order replacement parts, or optional accessories Part No. Description 4025204 Switch, Rocker, On-Off-On Part No. Description 4025206 Grill, Safety, Intake 4025299 Stand Hardware Kit 4025207 Grill, Safety, Exhaust 4036823 Motor 4025460 Quest Power Air Mover A3000...
  • Page 8: Warranty

    Limitations and Exclusions: This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC’s reasonable control. If any Quest Power Air Mover A3000 part is repaired or replaced, the new part shall be warranted for the balance of original warranty (but all warranty periods will be extended by the period of time, if any, that the Quest Power Air Mover A3000 with FOCUS Technology is out of service while awaiting covered warranty service). Warranty service will be performed during normal working hours. UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE QUEST Power Air Mover A3000 OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC,...