Installation Instructions

Before reading these instructions, please fold out the illustrated back pages.

Before installation

Important information:
Old appliances are not worthless
rubbish. Valuable raw materials can be
reclaimed by recycling old appliances.
Before disposing of your old appliance,
render it unusable.
You received your new appliance in a
protective shipping carton. All packaging
materials are environmentally friendly and
recyclable. Please contribute to a better
environment by disposing of packaging
materials in an environmentally-friendly
manner.
Please ask your dealer or inquire at your
local authority about current means of
disposal.
The extractor hood can be used in
exhaust-air or circulating-air mode.
Always attach the extractor hood
centred above the hotplates.
Minimum distance between hotplates
and lower edge of the extractor
hood: 650 mm.
Additional information for gas
cooking appliances:
Comply with the currently valid
installation regulations and the installation
instructions supplied by the gas appliance
manufacturers.
The extractor hood may be installed
with only one side next to a high-sided unit
or a high wall. Min. gap 50 mm.
The extractor hood must be installed at
a minimum distance of 650 mm above
gas hotplates – Fig. 5 – provided the fol-
lowing nominal heat loads (Hs) are not
exceeded:
❑ Gas cookers
Load of one hotplate
Load of all hotplates
Load of oven
6
❑ Gas hobs
❑ Gas ceramic hob
extractor hood and hotplates, the greater
the likelihood that rising water vapour will
condense under the extractor hood.
installed over a fireplace which burns solid
fuel (fire hazard due to flying sparks) if the
fireplace has a closed, non-detachable
cover and national regulations have been
observed. This restriction does not apply
to gas cookers and gas hobs.
Exhaust-air mode.
The exhaust air is conducted upwards via a
ventilation shaft or directly through the
outside wall into the atmosphere.
D
into a functioning smoke flue or exhaust-
gas flue or into a shaft which vents a room
with a fireplace.
Conveyance of exhaust air in a non-func-
tioning smoke flue or exhaust-gas flue
requires the prior consent of an appropriate
heating engineer.
D
mode and a flue-type heater is running
at the same time (e.g. gas, oil or solid-fuel
heaters, continuous-flow heaters, water
heaters), ensure that the fireplace has an
adequate air supply for combustion.
max. 03.0 kW
max. 08.3 kW
max. 03.9 kW
Load of one hotplate
Load of all hotplates
The specifications for nominal heat load
do not apply to closed gas ceramic
hobs.
Always comply with the specifications of
the hotplate manufacturer.
The smaller the distance between the
The extractor hood may only be
Fig. 6
The exhaust air must not be conveyed
If the extractor hood is in exhaust-air
max. 03.9 kW
max. 11.3 kW