Soberlink SL2 Training Manual

Soberlink SL2 Training Manual

Cellular device
Hide thumbs Also See for SL2:

Advertisement

Soberlink Cellular
Training Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Soberlink SL2

  • Page 1 Soberlink Cellular Training Manual...
  • Page 2: Table Of Contents

    Table of Contents Device Call-Outs Soberlink Cellular Device Diagram User Activation Device Activation & Client Enrollment Testing Guidelines Device Screens Tamper Prevention Restore Device to Factory Settings Device Specifications...
  • Page 3: Device Call-Outs

    Device Call-Outs Cellular Device Training Manual...
  • Page 4: Soberlink Cellular Device Diagram

    Device Diagram Left display button Camera Right display button Blue status light/Mouthpiece port LCD screen Power button Display buttons Power/Select button Cellular Device Training Manual...
  • Page 5: User Activation

    Portal. After updating the login credentials, the Admin will be able to create new Users from the Admin Tab. If the User’s email address is not yet confirmed in the Soberlink system, they will receive an Opt-In email. Note: The User must confirm the email address in order to receive any further communication from Soberlink.
  • Page 6 User Activation Security Questions After the welcome screen, the User will be prompted to select and answer three security questions. To complete the security questions follow these steps: 1. Click the drop-down arrows for each question. 2. Select the desired security question (each question may only be selected once).
  • Page 7 User Activation After completing the security questions, the User will create a new password. 1. Enter a new password that meets all of the displayed criteria. 2. Confirm the new password by entering it in the Confirm Password field. 3. Click Continue. Cellular Device Training Manual...
  • Page 8 User Activation When creating a new password, the criteria text will change according to whether or not it has been satisfied. Once the criteria has been met, all of the text will be green and have a check mark next to it. Cellular Device Training Manual...
  • Page 9: Device Activation & Client Enrollment

    Device Activation and Client Enrollment 1. Press the Power button on the Soberlink Device and log in to the Monitoring Web Portal. 2. On the Soberlink Device, select Start with the left display button. The Device will display the Device ID and Security PIN, and begin checking for activation on the Monitoring Web Portal.
  • Page 10 Enter the appropriate Client information in Steps 1 and 2 of the enrollment process. Step 1 Step 2 If the User has a Soberlink Device for the Client, click Yes in Step 3 to enter the Device ID, Security PIN, and payment information.
  • Page 11 Then click “Done” to finish enrolling the Client. Step 4 Once the Activation and Client Information have been accurately entered, the Soberlink Device will display a “Successfully Activated” message. On the Monitoring Web Portal the User will see a green check mark, indicating that the Device has been successfully activated and is ready for use.
  • Page 12: Testing Guidelines

    Testing Guidelines Use the Soberlink mouthpiece Sending A Test Turn on the Breathalyzer Follow the prompts on the screen Press the ‘submit’ button Hold the device at eye level Look directly into camera Take a deep breath Deliver a firm, steady stream of breath DON’T...
  • Page 13: Device Screens

    Device Screens Air Blank Test Menu Options Menu Options Use this feature to make sure To access or exit the Menu, Air Blank Test the Device’s fuel cell isn’t click both display buttons at Device 10000001 to select damaged. the same time. Date: --/--/-- Test history Time: --:--...
  • Page 14 Device Screens Error Screen Non-Compliant Retest The Device screen will After clicking “OK” on the Retest Required Test Has Not Been Sent display an error code to Wait 15 minutes previous retest screen, the help with troubleshooting. Device screen will display Additional test Cannot send test.
  • Page 15 Device Screens Charging Icon Queuing Compliant Test A battery icon will be If a Client attempts to Compliant Test displayed when the Device’s submit a compliant test Has Been Stored battery power is low but without cellular coverage, Test will be sent charging.
  • Page 16: Tamper Prevention

    Infrared Digital Camera Captures the identity of the Client with a high-resolution photo during a test. Lighted Blue Ring Assures the Soberlink mouthpiece is properly inserted for testing. Alternate Air Source Detection Detects air sources other than human breath (e.g. air pumps, canned air) by monitoring breath and ambient temperature.
  • Page 17: Restore Device To Factory Settings

    Highlight and select Reset Device. Then enter the button sequence: Power, Left, Right, Power. Once successfully reset, the Device will display the “Activation Required” screen. The Soberlink Device is ready to go back into inventory or be assigned to a new Client.
  • Page 18: Device Specifications

    Device Specifications Cellular Device Training Manual...