Inbeca Ecotouch User Manual

Inbeca Ecotouch User Manual

Control panel for steam bath

Advertisement

Quick Links

CONTROL PANEL FOR STEAM BATH ECOTOUCH

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ecotouch and is the answer not in the manual?

Questions and answers

Mohamed
March 18, 2025

Display showing blocked and asking to call service provider

1 comments:
Mr. Anderson
May 14, 2025

The Inbeca Ecotouch display may show as blocked and ask to call the service provider due to one of the following detected faults:

- Excess temperature triggering the security thermostat.
- The system fails to fill with water due to issues like no water supply, damaged fill valves, open fill valve, or damaged level probe.
- Broken or disconnected cable between the control panel and generator.
- Fan connected with reversed polarity.
- Ventilation turned off manually while the bath operates for more than 15 minutes.
- Water not evaporating after 20 minutes.
- Damaged level probes.

Each of these issues requires technical service intervention.

This answer is automatically generated

Summary of Contents for Inbeca Ecotouch

  • Page 1 CONTROL PANEL FOR STEAM BATH ECOTOUCH...
  • Page 2 Keyboard Function On / Off - ECO The equipment turns on with the ON / OFF key on the keyboard. On / Off - ECO Scent It can be turned on remotely connecting a pulse generator to the terminal blocks attached for that purpose Once it’s ON, display shows on the left, the current temperature value being calibrated by the probe, and on the right the desired temperature (selected).
  • Page 3 • Input and output panel: • Optical fibre cromotherapy (F.O.) Once optical fibre cromotherapy key is selected you will find 2 optional setting to establish the start-up / shutdown and the colour functions. Scroll through the menu with selection keys. In this panel we can see the state of the input and outputs. Access pressing Clock (7 and 8) keys during - On/off: Selection for turning on and off optical fibre cromotherapy. To turn it off press and hold the “ac- some seconds. In the diagram it is indicated the Meaning of the details showed in the panel: cept”...
  • Page 4 Troubleshooting: ----Sonda Temp..corto.Avisen serv.tec. The temperature probe has a short circuit. ----Sonda Temp.defet.Avisen serv.tec. The temperature probe give a value above the desired temperature so it means it is breakdown. ----Desagüe obturado.Avisen serv.tec. The system it is trying to fill up the boile. The drain it is colapsed, or the valve of fill up or level probe it is damaged. ----Detectada avería.Avisen serv.tec. Contact with the after sales service. ----Alarma temp.Avisen serv.tec.