v1-14805(N)
4/4
2-2-8. C
REC CURRENT
ADJ.
Measuring Point
Measuring Equipment
ADJ. Condition
TP181
Color bar generator
REC (SP) mode
(on VP-1 PWB)
Oscilloscope
Blank tape
(1:1 probe)
ALU Location
ADJ. Value
VR181 (REC-C)
150 mVp-p
* 5 mVp-p
1.
Connect
the ground
of the oscilloscope
totheshield
case
of the VP-1 PWB assembly.
2.
Adjust VR182 (REC-Y) for the minimum video luminance
signal level.
3.
Adjust VR181 (REC-C) so that the video chrominance
signal level is 150 mVpp
f 5 mVp-p. (Refer to Fig. 2.2.9)
WWCREC
150 mVp-p
Fig. 2.2.9
2-2-9. Y REC CURRENT
ADJ.
Measuring Point
Measuring Equipment
TP181
Color bar generator
(on W-1 PwB)
Oscilloscope
(1: 1 probe)
,
ALU Condition
Recode
Blank tape
L
I
ADJ. Location
I
AIXL Value
VR182 (REC-Y)
470 mVp-p * 10 mVp-p
1.
2.
Connect
the ground
of the oscilloscope
to the shield case
of the VP-1 PWB assembly.
Adjust VR182 (REC-Y) so that the video luminance signal
level at the sync tip is 470 mVp-p * 10 mVp-p. (Refer to
Fig. 2.2.10)
-YREC
mVp-p
Sy~c
Tip
Fig. 2.2.10
2-2-10.
VCO (on screen assist) ADJ.
1
I
I
(
Measuring Point
Measuring Equipment
ADJ. Condition
TP120
Color bar generator
E-E mode
Digital voltmeter
ADJ. Location
ADJ. Value
CT120 (VCO)
2.5 Vk 0.3 V
1.
Connect the digital voltmeter
(DC range) to TP120 and
GND.
2.
Adjust CT120 (VCO) so that the voltage is 2,5 V 10.3 V.
–11–