#15: Normal Schedules
The device allows to create multiple heating schedules to manage
temperature in the room throughout the week. Schedules are created
via controller interface or app.
•
up to 253 normal schedules can be created.
•
The lower the schedule ID number, the higher the priority.
•
Schedules with higher priority override those with lower priority
in case of overlapping schedules.
•
Schedules can be disabled without deleting it.
•
Schedules allow to set target temperature for HEAT mode (using
Thermostat Setpoint CC) and one of operating modes: HEAT, OFF
or MANuFACTuRER SPECIFIC (using Thermostat Mode CC)
•
Only SET commands are permitted.
To create normal schedules user must specify:
•
Day of the week,
•
Starting time (hour and minute),
•
Duration,
•
Temperature Setpoint for HEAT mode in range 10-30°C (using
Thermostat Setpoint CC)
•
One of the operating modes (using Thermostat Mode CC):
» HEAT for setting temperature,
» OFF for valve fully closed,
» MANuFACTuRER SPECIFIC for valve fully opened.
17
i
NOTE
Schedule CC Set com-
mand payload must
not be greater than
22 bytes limit or it
would be rejected.
NORMAL SCHEDuLES