Sigrand SG-17B User Manual

Sigrand SG-17B User Manual

Shdsl modem

Advertisement

«Sigrand» LLC
SHDSL modem
«Sigrand SG-17B»
User's manual
v. 3.0
Novosibirsk
2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG-17B and is the answer not in the manual?

Questions and answers

Summary of Contents for Sigrand SG-17B

  • Page 1 «Sigrand» LLC SHDSL modem «Sigrand SG-17B» User’s manual v. 3.0 Novosibirsk 2013...
  • Page 2 © «Sigrand», 2005 – 2013 All the trademarks, signs and copyrights associated with the items referred to in this document belong to the relevant right-holders. ТУ 6665-017-77565155-2007...
  • Page 3: Table Of Contents

    1. Description of the modem ..............7 1.1. Characteristics of the linear DSL interface ........8 1.1.1. Communication range and bitrate of Sigrand modem ....9 1.2. Characteristics of the Ethernet interface ........10 1.3. Characteristics of the RS-232C interface ........10 1.3.1.
  • Page 4 4. Updating the embedded software of the modem ......... 29 Guaranty and warranties ................33 WARRANTY CARD .................. 34 Appendix А ....................35...
  • Page 5: How To Use This «Manual

    How to use this «Manual…» To make this manual easier to use, the following icons and fonts are provided for: Icons Icon Meaning Explanation A section of this manual marked  with this icon can make it easier Take note of it! for you to set up and operate the device A paragraph marked with this...
  • Page 6: The Use Of Fonts In The Text

    Before you start setting up the modem, please visit our site  www.sigrand.ru and see whether there is a new version of this «Manual …» or an update of the firmware and drivers.
  • Page 7: Description Of The Modem

    Modems modifications SG-17B-441, SG-17B-351; Modems SG-17B-111, SG-17B-121, and SG-17B-141 are powered from a local power source with voltage 3.3, 12, or 48 V - in this case, SG-17B modems can be operated in combination with Sigrand non-function of the remote powering: •...
  • Page 8: Characteristics Of The Linear Dsl Interface

    The interface of SHDSL modem complies with ITU-T G.991.2.bis version (the version of 2005) and uses the TCPAM – Trellis-Coded Pulse Amplitude Modulation encoding set for data transfer. The modem is equipped with the following interfaces: • one SHDSL interface (ITU-T G.991.2.bis standard) operating in the bitrate range 192-15296 Kb per second;.
  • Page 9: Communication Range And Bitrate Of Sigrand Modem

    1.1.1. Communication range and bitrate of Sigrand modems Brief information on communication range and bitrate of Sigrand SG-17B modems is given in Table 1. The results were obtained with the length of lines providing the value of Bit Error Rate (BER) equal or less than 10 .
  • Page 10: Characteristics Of The Ethernet Interface

    1.2. Characteristics of the Ethernet interface Type of the interface 10/100 Base-T The number of ports Bitrate, Mb per second 10/100 Mode of operation Half- and full-duplex Compatibility ANSI/IEEE Std 802.3 Auto-sensing MDI/MDI-X Available 1.3. Characteristics of the RS-232C interface Bitrate, b per second 115 200 or 9600 Protocol...
  • Page 11: Power

    1.4. Power Modem series Sigrand SG-17B has modification with different type of power – ~220B, PoE receipt and delivery, a wide range of DC voltage: 12V, 24V, 48V and modification of the issuing and receiving the remote powering through a DSL line (Table 2).
  • Page 12: Remote Power Power-Over-Dsl (Podsl)

    1.4.1. Remote power Power-over-DSL (PoDSL) Remote power (PoDSL): Voltage, DC V Current, mA Output power, W Remote powering of the modem is carried through a DSL signal line. For the modems which has ability to obtain remote power, on the opposite side of the DSL line must be installed equipment supporting the power supply through the line.
  • Page 13: Power-Over-Ethernet Powering Of The Equipment

    The voltage of through-line powering is constant-current 48 Volt. The capacity of the devices hooked up through the system of through-line powering (for SG-17B-261 modem, the total of the capacities of the devices hooked up through the system of through-line powering and РоЕ) must not exceed 10 watt.
  • Page 14: Other Information

    PoDSL (17W), consumption modem through PoE will be about 20 W, which corresponds to the class of consumption PoE+. Modem power SG-17B-151 and SG-17B-351 for option "A" and "B" standard IEEE 802.3af. 1.5. Other information External dimensions of the modem case indoor: •...
  • Page 15: Scope Of Delivery

    Console control cable 1 item Wrapping 1 item Power supply unit is only delivered with SG-17B-111 modems and it is an AC/DC adapter of the following characteristics: input voltage 100- 240 VAC; output voltage 3.3 VDC. 1.7. Operating conditions The modem is designed to operate in the following environmental...
  • Page 16: Indicators And Sockets Indoor Case

    SHDSL, RS-232С, Ethernet, ground connection, as well as LEDs indicate the status of the device. Panel with connectors and indicators vary depending on the modification of the modem Fig. 4. Figure 4 Modems SG-17B-111, Modem SG-17B-541 SG-17B-121, SG-17B-141 Modem SG-17B-161...
  • Page 17 Modem SG-17B-351 Appointment sockets and switch in modem SG-17B. Table 4 LINE DSL interface socket ETHERNET Ethernet interface socket 10/100Base-T CONSOLE Control port socket for RS-232C POWER IN Local powering socket POWER OUT Through-line powering socket Ground connector Switch "PoDSL" Fig. 5 controls the remote power supply to the line DSL.
  • Page 18 Functions of Sigrand SG-17B indicators are shown in Table 5. Table 5 Indicator State Meaning POWER Lighted The modem is on Not Lighted The modem is off Lighted The modem is ready to work READY Not Lighted* The modem is not ready to work...
  • Page 19: Indicators And Sockets Outdoor Case

    1.8.2. Indicators and sockets outdoor case On the front panel of the modem in an outdoor case (Fig. 6) there are three cable glands, which allows to make a connection to the interfaces SHDSL, RS-232С and Ethernet. For the initial setup and connect the modem allowed delete a panel with the cable glands.
  • Page 20: Setting Up The Modem For Operation

    2.1.1. Specific features of connecting the modem to a PoDSL line With SG-17B-161 and SG-17B-261 modems, it is permissible to hook them up to a DSL line with voltage already fed there from a Sigrand device: • SG-17S with MS-17H4P2 modules;...
  • Page 21: Requirements For The Communication Line

    • Place the RJ-45 plug on the cable, according to (Fig. 7). Modem Sigrand SG-17B uses only one pair of wires, pins 4 and 5, the other pins are not used.. • Connect the cable socket to the DSL socket of the modem.
  • Page 22: Management Of The Modem

    Management of the modem Sigrand SG-17B modems are managed through the control port «CONSOLE» (Fig. 4) by means of RS-232C interface, through a computer where terminal software is installed. 3.1. How to link-up and set-up a terminal To set up a modem, its control port is to be connected to a serial port of the computer.
  • Page 23 Examples: "eth 100 full", "eth auto", "eth /auto" *********************************************************************** The info command will show the information on the version of the embedded software > info Sigrand SG-17BT v. 1.0 Firmware MC: SG-17BT v.1.0 Firmware IDC: v1.1_1.4.18 Firmware SDFE: v11.158.003 Firmware IAP: v1.0 UART >...
  • Page 24: Management Of The Dsl Interface

    3.3. Management of the DSL interface DSL interface is adjusting by use of the following commands: master | slave - set modem mode: master(CO) or slave(CPE) annexA|B - G.SHDSL.bis Annex type tcpamXXX - line coding, XXX={16,32,64,128} rate <value> - line rate plesio | plesio-ref|sync - Plesiochronous/Plesio-Ref/Synchronous modes pbo-normal|pbo-forced<val>...
  • Page 25: Choosing The Linear Encryption

    To make the optimal choice for the bitrate, the parameters of the line intended for the modems are to be taken into account. In case the line parameters are unknown, the following procedure is recommended to choose the bitrate: • Measure the line resistance with an ohmmeter (at one side, the wire pair is short-circuited and at the other side the measurement is carried out) and use Table 2 of Appendix to define the bitrate...
  • Page 26 Therefore, when setting up the bitrate of the communication line, special attention should be paid to the encryption algorithm TCPAM and, when necessary, the linear coding should be altered in order to produce the best possible results. In diagram 1, the permissible ranges of TCPAM encodings are shown. Diagram 1 192 Kbps 3840 Kbps...
  • Page 27: Adjusting The Auxiliary Dsl Parameters

    The commands plesio, plesio-ref, sync are used to set up the mode of synchronizing modems. In case the communication route is formed of modems Sg-17B<->Sg-17B, the mode of synchronization «sync» is recommended. Otherwise, modes «plesio» or «plesio-ref» are preferable, the choice being determined for each specific communication line empirically.
  • Page 28: Statistics Of The Shdsl Connection

    3.3.6. Statistics of the SHDSL connection To review the statistics of the connection, the command stat is used: > stat dsl_link: online SNR_Margin 19dB, Loop Attenuation 1dB, pbo_Value 6 ES_count 0, SES_count 0, CRC_Anomaly_count 0, LOSWS_count 0, UAS_count 0, Loss_count 0 •...
  • Page 29: Resetting The Connection

    Initialization of a new connection is defined by the option retrain: > retrain 3.4. Adjusting the Ethernet interface Sigrand SG-17B modems are equipped with a 10/100M Ethernet port, with the option of auto-sensing MDI/MDI-X. By default, the Ethernet port is arranged in the «auto» mode – with automatic speed/duplex adjusting.
  • Page 30 To initialize the process of updating the firmware, the following steps should be taken: • Disconnect the modem from the power source. • Connect the modem’s control port «CONSOLE» (Fig. 8) to the seri- al port (RS-232C) or to the USB port (in case a “Com <–> USB” cable adapter is used) of the computer.
  • Page 31 «3» should be entered. The update for a SHDSL chip consists of two firm- ware files with the extension «.bin », and is only available upon request to the «Sigrand» company. After «1», «2», or «3» is entered, a message appears with a request for...
  • Page 32 Then the location of the image-file aimed for updating the modem’s firm- ware should be specified. The form of an image-file is «*.bin». A firmware can contain several image-files. The process of updating is to be initiated for each file separately. The order of updating files is arbitrary.
  • Page 33 Warranty limitations : Warranty will become null for modems operated at «aerial» or combined («underground+aerial») lines. Manufacturer’s address: Av. Lavrentyeva, 6/6, Novosibirsk, Russian Federation, «Sigrand» LLC Тel.: (8-383) 332-94-37 Fax: (8-383) 332-02-43 www.sigrand.com...
  • Page 34 WARRANTY CARD for modem «Sigrand SG-17B» Serial № _________________________________________ Modification modem _____________________________________ produced in «____»_______20___. Checked by _______________/_____________/ locus sigilli Vendor Address Telephone Date of purchase locus sigilli Signature Buyer Address Telephone Date of purchase locus sigilli Signature...
  • Page 35 Appendix А Main characteristics of «ТПП» cable Table А.1. Frequency dependences for parameters of a twisted-pair cable with copper cores and polyethylene insulation (cables of «ТП» type) Secondary parameters Primary parameters α, dB/km R~, Ohm/km L, H/km *10 G, S/km *10 |Z|, Ohm Core diameter: 0.4 mm 5.51...

Table of Contents