BATTERY
Your tractor has a battery charging system which is suf fi cient
for normal use. However, periodic charging of the battery
with an automotive charger will extend its life.
Keep battery and terminals clean.
Keep battery bolts tight.
Keep small vent holes open.
Recharge at 6-10 amperes for 1 hour.
NOTE: The original equipment battery on your tractor is main-
tenance free. Do not attempt to open or remove caps or cov-
ers. Adding or checking level of electrolyte is not necessary.
TO CLEAN BATTERY AND TERMINALS
Corrosion and dirt on the battery and terminals can cause
the battery to "leak" power.
Raise seat.
Disconnect BLACK battery cable first then RED bat-
tery cable and remove battery from tractor.
Rinse the battery with plain water and dry.
Clean terminals and battery cable ends with wire brush
until bright.
Coat terminals with grease or petroleum jelly.
Reinstall battery (See "REPLACING BATTERY" in the
SERVICE AND ADJUSTMENTS section of this man u al).
V-BELTS
Check V-belts for deterioration and wear after 100 hours
of operation and replace if necessary. The belts are not
ad just able. Re place belts if they begin to slip from wear.
TRANSAXLE MAINTENANCE
Keep transaxle free from build-up of dirt and chaff which
can restrict cooling.
Do not attempt to clean transaxle while engine is running
or while the transaxle is hot. To prevent pos si ble damage
to seals, do not use high pressure water or steam to clean
transaxle.
ENGINE
LUBRICATION
Only use high quality detergent oil rated with API service
classification SG-SL. Select the oil's SAE viscosity grade
according to your expected operating temperature.
SAE VISCOSITY GRADES
5W-30
-20
0
30
F
C
-20
-30
-10
TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE
MAINTENANCE
SAE 30
32
40
60
80
0
10
20
30
Fig. 15
NOTE: Although multi-viscosity oils (5W30, 10W30 etc.)
improve starting in cold weather, they will result in increased
oil consumption when used above 32°F. Check your engine
oil level more frequently to avoid possible engine damage
from running low on oil.
Change the oil after every 25 hours of operation or at least
once a year if the tractor is not used for 25 hours in one year.
Check the crankcase oil level before starting the engine
and after each eight (8) hours of operation. Tighten oil fill
cap/dipstick securely each time you check the oil level.
TO CHANGE ENGINE OIL (See Figs. 15 & 16)
Determine temperature range expected before oil change.
All oil must meet API service classification SG-SL.
Be sure tractor is on level surface.
Oil will drain more freely when warm.
Catch oil in a suitable container.
Remove oil fill cap/dipstick. Be careful not to allow dirt
to enter the engine when changing oil.
Remove yellow cap from end of drain valve and install
the drain tube onto the fitting.
CLOSED
AND
LOCKED
POSITION
YEL LOW CAP
Unlock drain valve by pushing inward and turning
coun ter clock wise.
To open, pull out on the drain valve.
After oil has drained completely, close and lock the
drain valve by pushing inward and turning clockwise
until the pin is in the locked position as shown.
Remove the drain tube and replace the cap onto to the
bottom fitting of the drain valve.
Refill engine with oil through oil fill dipstick tube. Pour slowly.
Do not overfill. For approximate capacity see "PRODUCT
SPECIFICATIONS" section of this man u al.
Use gauge on oil fill cap/dipstick for checking level.
For accurate reading, insert dipstick into the tube and
push down firmly into place before removing. Keep oil
up to, but not over, the "FULL " line on dipstick. Push
dipstick down firmly into the tube when finished.