BSi BSICare User Manual

Telemedicine system for self-testing of glucose

Advertisement

Quick Links

User manual
Telemedicine System for
self-testing of glucose

Advertisement

loading
Need help?

Need help?

Do you have a question about the BSICare and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BSi BSICare

  • Page 1 User manual Telemedicine System for self-testing of glucose...
  • Page 2 Changing the BSICare settings BSICare bolus application Calculation of the bolus suggestion General recommendations Warnings Bolus suggestion settings and changing the BSICare bolus settings Procedure for the calculation of the suggestion bolus BSICare bolus glycemic diary Care and maintenance Replacing the batteries...
  • Page 3 The system BSICare is a system suitable for the quantitative determination of glucose in the blood, consisting of BSICare application, BSICare meter, BSICare strips and a device (smartphone or tablet) Android or iOS. In order to use the system correctly, you should read carefully the USER MANUAL of the meter and the INSTRUCTION FOR USE of the strips.
  • Page 4 09/2012 LOT: BSICare strips The proper use of the BSICare strips is very important to get accurate results. Please observe the following points: • The strips are sensitive to light and moisture, therefore store the strips only in their original vial.
  • Page 5 • Do not use damaged strips. • Read carefully the instruction for use contained in the strips package. • Take measurements only with original BSICare strips. • Do not touch the strips with wet or dirty hands. The applications...
  • Page 6 Warning! It is necessary to register on the website www.bsicare.it in order to send the data to the personal folder or to the structure by which you are followed.
  • Page 7 Only in the case of the BSICare bolus application, the obtained OFFLINE database can be transferred to the server after logging on with credentials. If you want to use the BSICare Bolus application, please see chapter page...
  • Page 8 How to get a drop of blood In order to perform a test with the BSICare system, it is necessary to collect a drop of capillary blood according to the following procedure: • Wash your hands thoroughly with warm water to intensify the blood circulation in the fingers and therefore to make easier the blood withdrawal.
  • Page 9 6. The display of the smartphone will show the message “INSERT A STRIP INTO THE BSICare” (fig.4). Take a strip out from the vial and insert it into the meter until it does not go any further, with the printed or colored side facing up.
  • Page 10 Start Result Bolus application display...
  • Page 11 Warnings IF YOU GET RESULTS WHICH DO NOT CORRESPOND TO YOUR HEALTH CONDITIONS AND TO YOUR FEELINGS, RUN THE CHECK OF THE METER USING THE CONTROL SO- LUTIONS AND ADVISE YOUR PHYSICIAN. IF YOU GET EXTREME VALUES, TOO HIGH (HI) OR TOO LOW (LO), CONTACT YOUR PHYSICIAN IMMEDIATELY. Once the testing is over, select the field or the symbol regarding the period of the measure- ment before saving.
  • Page 12 Glycemic diary The results are stored in the phone memory (maximum 2000 results). Procedure 1. Start the application. 2. Click on “DIARY”. 3. Once the list is shown, it is possible to filter the performed measures by time slot. 4. To go back, press the button...
  • Page 13 Changing the BSICare settings Start the application and enter the menu “SETTINGS”. It is possible to change the following parameters: . Language . Unit of measurement.
  • Page 14 BSICare bolus application Warning! The application shows only the word “BOLUS”, but it stands for “Bolus suggestion”. Read carefully before use. This section provides information regarding the function for calculating the bolus suggestion. BOLUS=suggestion Calculation of the bolus suggestion Warning: the bolus calculation is only a suggested quantity.
  • Page 15 The bolus suggestion function cannot edit mistakes of data entry, but can only warn you if you exceed the allowed limits for a given parameter. If the data are sent to the medical facility which is taking care of you, the parameters will be set up directly by the doctor through the web platform.
  • Page 16 Bolus suggestion settings and changing the BSICare bolus settings WARNINGS! When using the BSICare bolus application in OK mode (login) the settings for the suggestion bolus calculation must be inserted from the server. When using the BSICare bolus application in OFFLINE mode, enter the SETTINGS menu.
  • Page 17 Insulin sensitivity: Insulin sensitivity refers to the time period and indicates the amount of insulin necessary to lower the blood sugar at a certain level. The insulin sensitivity can be set for each of the seven time slots (necessary for the bolus calculation). These values will be set by your diabetologist.
  • Page 18 Neonatal usage is disabled. Do not enable when using with adults. In the bolus application when the function neonatal blood is enabled, the corresponding icon will appear during the measurement (not necessary for the bolus calculation). Mathematical basis of the bolus suggestion: Bolus suggestion= bolus meal + bolus correction - IOB (active insulin) The bolus meal is the amount of insulin (suggestion) as a function of the introduced carbohy- drates.
  • Page 19 The default unit of measurement in the meter is grams. WARNING! When using the BSICare Bolus application in the connected mode (login) the parameters for the calculation of the bolus suggestion must be set from the server and not on the device.
  • Page 20 BSICare bolus glycemic diary The results will be stored in the phone memory (maximum 2000 results). Procedure 1. Start the application. 2. Click on “DIARY”. It is possible to filter the performed measures by time slot. 3. Once the list is shown, it is possible to view the details, the averages, the standard deviations and the related graphics of the measurements.
  • Page 21: Care And Maintenance

    Warnings If the BSICare meter is too cold or too hot (eg. after being stored in a car at very low or high temperature), please allow it cooling down or heating up slowly at room temperature (it takes about 20 minutes).
  • Page 22 Please make sure that the new battery is the correct type of battery Displayed icons before inserting it. Full To replace the battery, follow these instructions: battery • Open the battery compartment at the rear of the meter (1). • Remove the old battery from the plastic support (2). Low battery •...
  • Page 23 In this way it is possible to learn how to use the BSICare meter and at the same time to check if it is working properly.
  • Page 24: Warranty

    BSICare will not be replaced. Biochemical Systems International Srl reserves the right to apply technical modifications to the BSICare meter without the obligation to include such changes to those products already introduced in the market.
  • Page 25 If the error remains, please contact exceeded the customer service Flat battery Please check if the BSICare is correctly inserted Empty Battery Wrong BSICare insertion Replace the battery Verify the BSICare inser- tion...
  • Page 26: Specifiche Tecniche

    Specifiche tecniche Model BSICare meter Sample volume 0,5 μL Reactive strips BSICare Range of measurement 20-600 mg/dL (1,1-33,3 mmol/L) Reading time 5 seconds Battery 1x3V mod. CR1620 Temperature thresholds 10-40°C (50-104°F) Humidity thresholds 10-90% RH Storage 5-30°C (41-86°F) Dimensions 43x30x14 mm...
  • Page 27 Warnings for the healthcare The BSICare strips contain the glucose oxidase, an enzyme specific for glucose. Therefore, they can be used on dialysis patients where the concentration of maltose in the blood increases, without the risk of false positives. The strips containing the enzyme glucose dehydrogenase together with the coenzyme PQQ (GDH-PQQ) determine glucose in a less specific way instead, and, therefore, they are influenced by high concentrations of other sugars in the blood.
  • Page 28 Biochemical Systems International S.r.l. Via G. Ferraris, 220 - 52100 Arezzo - Italia www.biosys.it / biosys@biosys.it Tel. 0039 0575 984164 - Fax +39 0575 984238 0344 MBSIC IT ED2015 Maggio...