Central Boiler Fire Star II Operation Manual

Central Boiler Fire Star II Operation Manual

Hide thumbs Also See for Fire Star II:

Advertisement

For parts and accessories, service or repairs, call your authorized Central Boiler dealer or heating
contractor. Record the information below for future reference.
Serial Number
Dealership Name
Owner Name
OPERATION MANUAL
Press to
Reset
II
II
If Enabled
Press to
Prime
Installation Date
Phone Number
SOFTWARE VERSION 2.5
Save This Manual
For Future Reference
9-JAN-2017 • (p/n 9000317 - REV. D)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fire Star II and is the answer not in the manual?

Questions and answers

Summary of Contents for Central Boiler Fire Star II

  • Page 1 SOFTWARE VERSION 2.5 If Enabled Press to Prime Press to Reset For parts and accessories, service or repairs, call your authorized Central Boiler dealer or heating contractor. Record the information below for future reference. Serial Number Installation Date Dealership Name Phone Number...
  • Page 2 ™ by Central Boiler, Inc. 20502 160th Street • Greenbush, MN 56726 CentralBoiler.com • MaximHeat.com NOTE: Any person(s) operating a hydronic heater must comply with all applicable laws, including but not limited to local ordinances.
  • Page 3 FIRESTAR CONTROLLER (version 2.5) 3. The heat output (fuel feed rate) settings in each of the three modes (HIGH / MEDIUM / LOW) may be changed here using the buttons. During operation, the light bar will indicate the heat output setting for the mode the combustion controller is currently in.
  • Page 4: Initial Start-Up

    Initial Start-up NOTE: Before starting the outdoor furnace, NOTE: Upon initial start-up, it is not uncommon make sure that (1) the proper amount of 1650XL for a substantial amount of condensation to be Inhibitor Plus has been added and the water level present in the firebox as the furnace is coming up is full;...
  • Page 5 Setting the FireStar Controller for Fuel Type, Heat Load and Efficiency The controller’s default settings allow the furnace Heat Output Settings to operate properly in most installations without For best results, determine the lowest water temperature adjustment. These settings can be adjusted, however, for setpoint the outdoor furnace can be set to, while still installations that require matching the furnace output to supplying enough heat to the heat emitters.
  • Page 6: Understanding Operating Modes

    Understanding Operating Modes LOW Mode (If Enabled) MEDIUM Mode In general, the MEDIUM heat output setting should NOTE: LOW mode should only be enabled if there be set high enough to minimize the amount of time the is a problem with the electric ignitor. Contact your controller is in HIGH mode.
  • Page 7 HIGH Mode To View All Heat Output Settings: The reason the FireStar combustion controller has a 1. Press any of the buttons for the HIGH, MEDIUM and HIGH heat output setting is for efficiency. MEDIUM or LOW modes. The light bars will The most efficient setting for the HIGH mode is when display the current heat output settings.
  • Page 8: Air Settings

    Air Settings Air Settings When LOW Mode is Enabled To View the Current Air Settings: The air setting for LOW mode increases or decreases 1. Press and hold the Air Adjust button. The light the length of time the fan runs each time the auger turns. bars will display the current air setting for each mode.
  • Page 9 Ignition / Clean Out Mode Ignition Clean Out Mode The combustion controller continuously monitors the Situations may arise when it becomes necessary to burner temperature when in MEDIUM mode and there empty all of the fuel from the burner auger (e.g., for is a call for heat.
  • Page 10: Led Display Alarm Definitions

    If adding water does not correct the problem, To clear the Fire Out alarm, turn the combustion contact your Central Boiler dealer. controller off and on again or press and hold the Reset button.
  • Page 11: Setup Mode

    Setup Mode To Enter Setup Mode 4. Ignition Burner Temperature: 300˚F (149˚C) Press and hold the Water Temp button for at least 7 The combustion controller will operate in Ignition seconds until the LED display changes from the water Mode until the burner temperature reaches this value temperature to plus the Ignition Differential (variable 5).
  • Page 12 The combustion controller can be locked to prevent minute and then try again. If that does correct an unauthorized access to the combustion controller apparent error, contact your Central Boiler dealer. settings. To lock the combustion controller: Press the Water Temp button four times within three seconds.