loading
Need help?

Need help?

Do you have a question about the GUARDSCAN GS120 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GIGA-TMS GUARDSCAN GS120

  • Page 1 JAN 2008 REGISTERED TO ISO 9001:2000 8F, No.31, Lane 169, Kang-Ning St., Hsi-Chih Taipei Hsien, 221 Taiwan Phone: (886) 2-2695-4214 FAX: (886) 2-2695-4213 www.gigatms.com.tw...
  • Page 2: Information

    Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of GIGA-TMS INC. REVISIONS...
  • Page 3 Contents ....................Information ..........Technical and Operational Description ....................Connections ..................Card Data Format ....................Specifications ..............Communication Protocol FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 4 Information GS120 Series 125KHz RFID Reader MACHINE TYPE FUNCTION Muti-Battery F - MEM Single Cell NiHM / NiCd LR03 / AAA 512 KB ALKALINE 125K RS-232 8192 BEEP REC QUEUE AUTO GS120 VER 1.2 RS232 Interface Muti-Battery F - MEM Single Cell NiHM / NiCd LR03 / AAA...
  • Page 5 Information Standard Package LR03-AAA ALKALINE 1.5V Battery Main unit ( BAT-T0010 ) ( GS120 ) Chain Sling CD-ROM ( TM09F1001 ) RS232 Cable ( WAS-T0017 ) RS232 Cable for GS120 series USB Cable for GS120U series ( WAS-T0017 ) ( WAS-1571 )
  • Page 6: Technical And Operational Description

    Technical and Operational Description Front Panel and Operations LCD Main Screen Operation LED Indicator Connector Operate Keypad Chain Sling Hole RFID Card Scan Area Battery Box RFID Card Scan Area Scan the RFID card to reader. Operation LED Indicator When encountering erroneous input, defective card, misread,bad memory or incorrectly encoded data and so on, the device will turn on the ERROR indicator .
  • Page 7 Technical And Operational Description LCD Display Status Function Area Main Display Area Keypad Guidance Area PROMAG Status Function Area 1. Power Status 4. Decode Status Battery Power Supply EM Card Decoded Low Battery Power Supply 5. Guidance Number External Power Supply xxxxxx Current Record Number When Scanning or 2.
  • Page 8 Technical And Operational Description Function Menu Display Machine ID - 1-1. Machine ID 2 Characters Default : 00 Display User Name - 1-2. User Name 16 Characters Max Display Mode - 1-3. Display Format 1. Profiles ID Number Set View Mode - 1-4.
  • Page 9 Technical and Operational Description Display Information Exceptional Indication LCD Display message Description Counterplot The RTC is malfunctioning Check RTC ! Set Date and Time ( After scan card ) The record already is full. Download Records FLASH Full ! ( After scan card ) and Erase Records The record can’t write into the FLASH memory.
  • Page 10 Technical and Operational Description Operational Description 1. Powered by Battery “ “ For normal use, the unit is powered by battery. Push the Power Switch Button for about 2 seconds to turn on the “ “ unit. Also push the Power Switch Button for about 2 seconds to turn off the unit at Switch Mode.
  • Page 11 Technical and Operational Description Replacing Battery Note: 1. Read the instructions on your device before replace new battery. 2. GS120 can use Single-cell alkaline, nickel-cadmium (NiCd), or nickel-metal hydride (NiMH) Battery 1. Power turn off 4. Take new battery 2. Take the cover away 5.
  • Page 12 WAS-T0017 RS232 interface cable DSUB 9P POWER JACK DSUB 9P FEMALE PIN FUNCTION MINI USB 4P VCC +5V No use Connect to PC RS-232 PORT GS120 Personal Computer External power DC +5V Note: 1. When GS120 is connected/disconnected with an external power adapter, it would be turned On/Off automatically.
  • Page 13: Connections

    Connections WAS-1571 USB interface cable USB 4P FEMALE PIN FUNCTION MINI USB 4P FUNCTION Connect to PC PORT GS120 Personal Computer Note: 1. When GS120 is connected/disconnected with USB port, it would be turned On/Off automatically.
  • Page 14 CARD DATA STRING DATE & TIME CARD TYPE 10 CARD ID DATE TIME CARD TYPE CARD ID DATE & TIME DATE TIME YYYY/MM/DD HH:MM:SS 1. SP is the SPACE characters ( 20h ). 2. TIME is 24hrs . CARD TYPE CARD TYPE EM 125K...
  • Page 15: Specifications

    125KHz RFID Card for GS120 EM compatible64 bits, ASK Manchester coding. Reading distance 10~50mm (depends on card). RS-232 RS232 Interface RS232 , Half-Duplex , 8N1 , 19200 bps USB Interface Ver 1.1 Full compliance with the USB Specification V 1.1 The device uses a Virtual Serial Port Driver, making it appear to have the software like a standard RS232 Serial Port.
  • Page 16 Handshaking NACK NACK TIME OUT TIME WAIT NACK NACK PACKET CONTENTS REPLY CONTENTS ITEM Control Key Function Start of Text ASCII ASCII ASCII Command Code CONTENTS ASCII ASCII ASCII Contents Data CHKSUM ASCII ASCII ASCII Check Sum Carriage Return REPLY (78) 65 (4e) 41 (N) A...
  • Page 17: Communication Protocol

    Communication Protocol GS120 Terminal has an extensive list of Commands that allow manipulating its internal database, setting functional parameters and getting data on its current status. There are 2 levels of access to the GS120 : User and Supervisor. Supervisor level is protected by a Password.
  • Page 18 Communication Protocol Access Security Commands LOGIN : (for Supervisor Access Level) PASSWORD A or D or I PASSWORD 4 Characters for Login. 0000=Initial value EXAMPLE 0000 Login password : 0000 Login password command is not executed. Invalid password. LOGOUT : EXAMPLE Logout SET PASSWORD :...
  • Page 19 Communication Protocol EXAMPLE 1234 Set new password : 1234 Set new password is not executed. Invalid password GET NUMBER OF RECORD : NUMBER NUMBER Record Count . 4 Bytes Width ( 0000h ~ 0800h ) EXAMPLE 000C The total of record count : 12 READ RECORD BY NUMBER : DATE TIME DATA...
  • Page 20 Communication Protocol ERASE ALL RECORD : * ( Erase Duration : < 60 seconds ) A or D EXAMPLE Erase all records. Erase command is not executed. ROLLBACK DATABASE READOUT TRANSACTION : A or D EXAMPLE Database is rollback. Command is not executed. RECOVERY ALL DATABASE READOUT TRANSACTION : A or I EXAMPLE...
  • Page 21 Communication Protocol GET PRODUCT VERSION : ROM No. VERSION ROM No. ROM-Txxxx , xxxx : Rom serial number VERSION Vx.xxRm , Vx.xx : Firmware version x.xx , Rm : Modify m times EXAMPLE ROM-T0842 V1.00R1 ROM serial number = ROM-T0842 Firmware version = 1.00 Modify times = 1 SET DATE AND TIME :...
  • Page 22 Communication Protocol GET DATE AND TIME: YYYYMMDDhhmmss EXAMPLE 20000506123000 Get Date = 2000 / 5 / 6 Get Time = 12 : 30 : 00 Get Date/Time is not set or invalid. SET MACHINE ID: 00~255 A or I or D EXAMPLE Set Machine ID : 00 Invalid command or data.
  • Page 23 Communication Protocol GET MACHINE : 00~255 EXAMPLE Get Machine ID : 00 Get Identification is not set or otherwise invalid. ENTER FIRMWARE MANAGEMENT MODE : EXAMPLE Enter firmware management mode...
  • Page 24 Communication Protocol SET REGISTER : REGISTER PARAM CHKSUM REGISTER Register Address . 2 Bytes Width ( 00h ~ FFh ) PARAM Set Parameters of Register CHKSUM C + REGISTER + , + PARAM GET REGISTER : REGSTER PARAM CHKSUM REGISTER Register Address .