1.0 General 2.0 Product Versions 1.1 Information 2.1 Model The operating instructions are handed over together with Electrical the sliding door driving mechanism. They serve as sup- Manuell porting material for the user in case of questions as to omatic Half –...
2.9 Terminal (optional) Changes of parameter are to be made only by authorized service personell. Inappropriate changes of the parameter values will revoke the man- ufacturers liability/warranty for damage resulting from it. Example: Changing of the open time >COMPLETELY OPEN 1< >Terminal display in automatic mode<...
Page 5
Use the <E> key to acknowledge the selected para- Parameter 61 = select 1. meter. (Use the <P> key to abort the process) >Display PS mode< Use the <+> or <-> key to select the desired mode >Display of the current parameter value< Use the <+>or <->...
3.0 Range of application 5.0 Putting into operation The setting up of the driving mechanism for the putting 3.1 Application Area into operation procedure described below must be re- peated after each technical modification. The driving mechanism has exclusively been designed for indoor use and for locations meeting similar require- 5.1 Precondition ments only.
400 mm and after wards ex- ecutes the respective opening function. Two or more S4000 driving mechanisms can be mutually interlocked. As soon as one door is open/opened, the Emergency opening in case of power failure without...
This safety check must be carried §13 no.4 par. 1, if the customer has decided not to out by technical personell trained by Reisinger assign the safety check work to the contractor during GmbH. Any intervention by a third party will result in the period of limitation.”...
9.0 Parameters 9.1 Parameter list Terminal / RS232 Designation Designation Designation Ter- Designation Works set- min. max. Unit Works setting min. max. RS232 minal RS232 ting Terminal Time PARTLY Time PARTLY 51 Special function Special function OPEN OPEN Time COMPLETELY Time COMPLETELY Summer/winter 53 Summer/winter...
9.2 Terms used on parameter list Time The time the door remains in OPEN position; unit seconds. Width The width is the travel path of the door from CLOSE position to OPEN position; unit millimeters. Running-in zone The driving unit has two running-in zones – one before reaching the CLOSE position and one before reaching the OPEN position.
Page 11
Parameter 22 : Travelling speed in CLOSE direction. The parameter value should be between 100 mm/s and 200 mm/s. In case of any change in speed, a new teach-in run must be carried out! Parameter 23 : Travelling speed to the OPEN/CLOSE end positions. The parameter value should be between 10 mm/s and 30 mm/s.
Page 12
Parameter 51: Special functions: special input SO 0 – no function 1 – input (NO contact) SO activated – emergency opening in case of interlocking; door OPENS and remains in this position, until SI is deactivated. This opening of the door is indicated by an acous- tic signal.
Page 13
Parameter 76 Activation lock time closing time 1 0 – normal mode 1 – closing time mode Parameter 77 Activation lock time closing time 2 0 – normal mode 1 – closing time mode Parameter 78 Activation lock time closing time 3 0 –...
Select font and size: 10.0 Setup by RS232 (PC, notebook) For the comfortable set-up of the S 4000 a terminal pro- gram (Hyper terminal) and a data cable (item number KA101.1005) are required. You will find the program un- der Programs/Accessories. (Windows 98,ME,2000,XP) 10.1 Configuration Before the first start the following connection settings must be entered.
10.2 List Start command: sys Page 1: Automatic door S 4000 ETyp: 123 5 Reisinger GmbH (c) 2008 V 1.10 S/N : 0751001 MTyp: SK -------------------------------------------------------------------------------------- 1. Time partial open [ s] 21. Speed open 221 [mm/s] 2. Time full open 1 [ s] 22.