Reisinger S 3000 Operating Instructions Manual

Sliding door driving mechanism

Advertisement

O
I
PERATING
NSTRUCTIONS
S
D
D
M
LIDING
OOR
RIVING
ECHANISM
S 3000
V1.38EN
19.12.05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Reisinger S 3000

  • Page 1 PERATING NSTRUCTIONS LIDING RIVING ECHANISM S 3000 V1.38EN 19.12.05...
  • Page 2: Table Of Contents

    Table of contents of operating instructions 1.0 General..........................3 1.1 Information 2.0 Product description ....................... 3 2.1 Designation / Model 2.2 Design 2.3 Driving mechanism 2.4 Components (optional) 2.5 Terminal 2.5.1 Basic function 2.5.2 Operating states 2.5.3 Key function 2.5.4 Parameter settings 2.5.5 Programm selector 2.6 Technical data 3.0 Scope of application .....................
  • Page 3: General

     DIN left or DIN right (right-/left-handed opening) The operating instructions are handed over together with the sliding door driving mechanism. They serve as sup-  S 3000 one-wing porting material for the user in case of questions as to  S 3000 two-wing the professional use and as a basis for the mechanic on ...
  • Page 4: Basic Function

    (optional) 2.5 Terminal 2.5.4 Parameter settings The parameters are preset at works according to your requirements and to the relevant standards. Parameter modifications must only be carried out by authorised staff. Improper modifications of the pa- rameter values will exclude any liability of the manufac- turer for damages resulting therefrom.
  • Page 5: Programm Selector

    Example: PS mode >Closing time< >Display after pressing <+> key Use the <E> key to acknowledge the selected pa- >Standard display, PS inactive< rameter. (Use the <P> key to abort the process) Parameter 61 = select 1. >Display of the current p arameter value< >Display PS mode <...
  • Page 6: Technical Data

    2.6 Technical data 4.0 Assembly  Supply voltage: 230V~ 50/60Hz Only authorized technical staff is allowed to carry out the assembly of the driving mechanism. The compulsory in- (optional) 120V~ 50/60Hz struction on our premises is the basis for proper assem- ...
  • Page 7: Fault Clearance During Putting Into Operation Procedure

    External interlocking fucntion (K1/LOC [10,11/12,13] ) 5.3 Fault clearance during putting into opera- tion procedure module 3 A mutual interlocking with an external door is possible. If a fault occurs, all previous technical modifications will As soon as one door is open/opened, the locking moni- have to be checked.
  • Page 8: Maintenance / Safety Check

    7.0 Maintenance / Safety check According to the professional association direc- A due safety check of the S 3000 is indicated by the yel- tives BGR 232, power-operated windows, doors and low LED at the motor unit and/or the terminal. The gates must be checked for safe operation before their maximum checking interval is 12 months .
  • Page 9: Parameters

    9.0 Parameters 9.1 Parameter list Terminal / RS232 Designation Designation Designati on Designation W orks min. max. Unit Works setting min. max. Terminal RS232 Terminal RS232 setting T ime PARTLY Time PARTLY 51 Special function Special function OPEN OPEN Time Time COMPLETELY Teach-in run with- Teach-in run with-...
  • Page 10: Explanations Regarding Parameter List

    9.2 Explanations regarding parameter list Time The time the door remains in OPEN position; unit seconds. Width The width is the travel path of the door from CLOSE position to OPEN position; unit millimeters. Running-in zone The driving unit has two running-in zones – one before reaching the CLOSE position and one before reaching the OPEN position.
  • Page 11 In case in any change in speed, a new teach-in run must be carried out ! Travelling speed in OPEN direction. The parameter value should be between 100 and 150. This Parameter 21 : means a speed of approx. 520 mm/s, depending on the door weight. In case of any change in speed, a new teach-in run must be carried out! Parameter 22 : Travelling speed in CLOSE direction.
  • Page 12 Parameter 51: Special functions: special input SI 0 – no function 1 – input (NO contact) SI activated – emergency opening in case of interlocking; door OPENS and remains in this position, until SI is deactivated. This opening of the door is indicated by an acoustic signal.
  • Page 13 Parameter 77 Activation lock time closing time 2 0 – normal mode 1 – closing time mode Parameter 78 Activation lock time closing time 3 0 – normal mode 1 – closing time mode Example : The motion sensor Outside is locked from 6 p.m. until 8 a.m. 1.
  • Page 14: Setup Via Rs232 (Pc, Notebook)

     Select font and size: 10.0 Setup via RS232 (PC, notebook) For the comfortable set-up of the S 3000 a terminal pro- gram (Hyper terminal) and a data cable (item number KA101.1005) are required. You will find the program un- der Programs/Accessories.
  • Page 15: List

    10.2 List  Start command: sys Page 1 Sliding door driving mechanism S 3000 EType:12345 Reisinger GmbH (c) 2005 V 1.380 S/N : 0401001 MType:STANDARD -------------------------------------------------------------------------------- 1. Time PARTLY OPEN 1 [ s] 21. Speed OPEN 144 [--] 2. Time COMPLETELY OPEN 1 12 [ s] 22.
  • Page 16: Terminal Diagrams

    11.0 Terminal diagrams 11.1 Cable laying diagram 16 –...
  • Page 17: Terminal Assignment

    11.2 Terminal assignment 51/05 - 17 –...
  • Page 18: Dimensions

    12.0 Dimensions 12.1 Sectional drawing one-wing drive 18 –...
  • Page 19: Sectional Drawing Telescopic And Two-Wing Drive

    12.2 Sectional drawing telescopic and two-wing drive 51/05 - 19 –...