Advertisement

Quick Links

Local Air Conditioner
Thank you for selecting this air-conditioner. Please keep this User's Manual for future reference.
Read the User's Manual carefully before operating this unit.
IMPORTANT SAFEGUARDS
• This air-conditioner is suitable for indoor use only.
• Rated operating range: this unit shall be connected to 220-240V / 50Hz power supply.
• Ensure this is used on a flat surface at least 50cm away from surrounding objects or walls.
• Once the air-conditioner is installed, ensure that the mains cable is in good condition and
inserted firmly into the power socket and always ensure that the power cord is arranged in
such a way to avoid tripping or the plug from being pulled out.
• Do not insert any object into the air inlet/outlet of the air-conditioner. Be sure to keep the
air inlet/outlet of the air-conditioner unblocked.
• Where there is the need to install a drain pipe, ensure that the connection of the drain
pipe is secure without kinks.
• When adjusting the horizontal/vertical louver at the air outlet, turn it slightly by hand to
avoid damage of the Louvre.
• Keep the unit in an upright position when moving or repositioning.
• Keep this unit away from petrol, flammable gases, or other heat sources.
• Do not dismantle, inspect or modify the unit without authorisation as this may impair the
unit, cause personal injuries or property damage; to avoid dangers, if the unit is faulty, be
sure to have it repaired by the manufacturer or a suitable qualified person.
• Do not operate this air-conditioner in a bathroom or other wet environments.
• Do not allow children to play with this machine. Closely supervise children when this unit
is in use.
• Do not turn off this unit by removing the plug.
• Do not place liquids on the unit.
• Do not use pest control aerosol or other flammable substances near the air-conditioner.
• Do not wipe or wash the air-conditioner with chemical solvents such as petroleum, aerosol or
alcohols, etc. Before cleaning the air-conditioner, be sure to turn off the power supply
and wipe it with a soft damp cloth; if the machine is very dirty, wipe it with a neutral cleaner.
RECOMMENDATION
Do not operate this unit if the ambient temperature is greater than 35˚C in the cooling mode or
lower than 5˚C in the heating mode.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RHINO FSD

  • Page 1 Local Air Conditioner Thank you for selecting this air-conditioner. Please keep this User’s Manual for future reference. Read the User’s Manual carefully before operating this unit. IMPORTANT SAFEGUARDS • This air-conditioner is suitable for indoor use only. • Rated operating range: this unit shall be connected to 220-240V / 50Hz power supply. •...
  • Page 2: Function Description

    FUNCTION DESCRIPTION The mobile air-conditioner has the following functions available cooling, dry, air blowing and sleep functions. The speed of the fan is adjustable between high fan speed and low fan speed, and various functions such as (24h) timed ON/OFF setting. FEATURES AND PARTS 1.
  • Page 3: Installation Adjustment

    1. Control panel 14. Lower air duct 2. Horizontal louvre 15. Cable winding post 3. Vertical louvre 16. Drain cap 4. Air outlet frame 17. Evaporator filter mesh 5. Vertical Louvre connecting lever 18. Evaporator filter frame 6. Caster 19. Radiating fine mesh 7.
  • Page 4 b) Rotate the exhaust clip counter-clockwise until the clip locks firmly into position as shown below (as shown in Figure 2). Note Do not rotate exhaust clip if not correctly aligned as this may damage the interlocking components. c) Installation of the exhaust hose assembly to the unit Pull the end of the exhaust hose apart to allow easy access to the exhaust connector ;...
  • Page 5 Figure 5 Figure 6 Open the ducting hose and position the outlet Figure 7 of the hose into a well ventilated area. The exhaust hose may not be bent and shall be free from significant kinks (greater than 45°). Note The exhaust hose is 280mm-1000mm long.
  • Page 6: Control Setting

    CONTROL SETTING One. Operation instructions of the control panel 1. Select the operation mode depending on the model and functions. The operation mode is as follows: Celsius degree Regular time Double 8 Fahrenheit indicator indicator display area degree indicator Timer button ON/OFF button TIMER POWER...
  • Page 7 2. Operation instructions: a) In the Cooling models: Ta≥Ts+1˚C (1˚F), the cooling starting. Ta≤Ts-1˚C (1˚F), the compressor stops and only the fan motor remains working at the set fan speed. Ta: Room Surrounding Temperature Ts: Setting Temperature Sleep mode, pressing Timer and Down button can set the sleep function. In sleep function, after operating two hours, the set temperature increases 1˚C (1˚F) automatically.
  • Page 8: Remote Control

    5. Multiple protection functions: a) Anti-freeze protection function: Upon cooling, when the compressors operates continuously for more than 10 minutes, if the pipe temperature Tp is less than or equal to 2˚C continuously for 20 seconds, the compressor will turn off, LED displays E4, the unit initiates the anti-frost protection function and the buttons are inactive (except the OFF button).
  • Page 9: Water Drainage

    WATER DRAINAGE 1. Manual drain: (as shown in Figure 10) a) Once the unit shuts down upon full water, turn off the power of the unit and then unplug the power plug. Note: move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit.
  • Page 10: Maintenance And Servicing

    Figure 13 Figure 14 Gripping Gripping position position Gripping Gripping position position MAINTENANCE AND SERVICING 1) Prior to maintenance and servicing of the unit, turn off the power and unplug the plug. a) Surface cleaning Clean the surface of the unit with a clean damp soft cloth. Do not use chemical solvents such as alcohol and petrol;...
  • Page 11: Handling Of The Unit

    HANDLING OF THE UNIT Figure 16 Handling and moving of the unit To handle or move the unit, hold the top of the air outlet of the front shell with one hand and the handle position at the top of the back shell with Remote control another hand, ensure the unit remains in the...
  • Page 12: Troubleshooting

    Capillary APPENDIX Fuse parameters Condenser Model: FSD or 50F Voltage: 240V Current: 3.15A Compressor Evaporator Schematic diagram of the air-conditioner For specific technical parameters of the models, refer to the rating label on the product.

This manual is also suitable for:

50f

Table of Contents