Download Print this page

Samsung SSA-R2001V User Manual page 12

Rfid reader

Advertisement

initialization
BASIC OPERATIONS
Initial State (when the power is supplied)
When you apply power to the product, it will sound beep fi ve times before entering Standby with the red indicator
turned on.
Using the card
Present the card to the product until you hear a beep and the green indicator turns on.
The reader keeps the green indicator turned on while transferring the card data to the
controller.
When it is done, the green indicator turns off and for receiving the next card, the red
indicator stays ON.
Using the keypad
Hold down the keypad until you hear a beep. As soon as you press the keypad, the yellow indicator turns on,
followed by the reader transferring the keypad data to the controller.
LED Control
You can control both green and orange indicators at will.
To control the green indicator, connect the green-indicator control line (yellow) to NO of the controller relay output,
and connect COM to GND. Set I/O of the controller; now you can control turning on/off the indicator.
You can turn on/off the indicators according to the I/O settings of the controller, which can be applied to various
situations.
For more information about the I/O settings of the controller, refer to the user manual of the controller.
To control the orange indicator, connect the gray line to NO of the controller.
Buzzer Control
Connect the buzzer control input line (blue) to the NO port of the controller relay output, and GND to the COM port.
You can confi gure the I/O settings of the controller so that it beeps. If the product continues to beep, it means that
the buzzer control is working properly.
The controller can use the I/O settings to set the buzzer control so that it sounds an additional beep for authorized
or unauthorized access upon user authentication.
Furthermore, you can make various modifi cations according to the different I/O settings of the controller.
For more information about the I/O settings of the controller, refer to the user manual of the controller.
Card reading is not available while the buzzer control is sounding the buzzer.
Tamper Control
You can set the signal that you want to output if the device is dismantled forcibly.
Connect the COM port (Pink line) of the product's tamper switch to GND; connect the NC port (Light yellow) of the
tamper switch to the input port of the controller. If the tamper of the reader operates, the controller produces an input
signal and generates the corresponding output depending on the controller setting.
12_
initialization
SSA-R2001V

Advertisement

loading