Summary of Contents for Calorex ACT-7

  • Page 1 ACT-7 Quick start guide...
  • Page 2: Health And Safety

    ACT-7 QUICK START GUIDE...
  • Page 3: Table Of Contents

    Air fl ow Troubleshooting The air outlet at th e top of th e ACT-7 room unit is fi tted with grilles th at allow th e angle of air outlet to be adjusted. In conjunction with th e fan speed control switch, th e air velocity and direction can be carefully set up to obtain maximum coverage of th e area being cooled with out causing draughts.
  • Page 4: Siting

    (fi ve screws). The switch is located at th e back of length of th e room. If th ere is more th an one ACT-7 in th e th e electric box in th e position shown below. Change th e...
  • Page 5: Condensate

    8.1 litres/1.78 gallons Room unit fl uid level 9.5 litres/2.08 gallons The fl uid system in th e ACT-7 room unit should be at th e 10.9 litres/2.39 gallons correct level when delivered. Look th rough th e inspection 12.3 litres/2.70 gallons window and check th at th e level is between th e MAX and MIN on th e tank in th e back of th e room unit.
  • Page 6: Controls

    There is a six minute delay timer when switching to ‘A/C’ for ducted operation). mode from ‘stand by’ or ‘fan only’ modes. Cooling will start aft er th is delay period. ACT-7 QUICK START GUIDE...
  • Page 7: Setting Th E Desired Temperature

    ‘down’ ‘enter’ Temperature Reset alarm With th e ‘Temperature’ option highlighted press th e ‘enter’ key. Use th e ‘up’ and ‘down’ keys to change th e highlighted value. Pressing enter stores th e temperature setting. ACT-7 QUICK START GUIDE...
  • Page 8: Fault Symbols

    Reset Alarms HP Fault LP Fault In th e ‘Settings menu’ scroll down to ‘Reset alarm’ and push ‘enter’. Then using th e up and down keys highlight th e alarm to be reset and push ‘enter’. ACT-7 QUICK START GUIDE...
  • Page 9 When th e condensate tank in th e ACT-7 is full, a blue bucket fl ashes on th e console. While th is is fl ashing th e ACT-7 continues to work for a furth er 30 seconds.
  • Page 10: Changing Th E Off Set

    In th e ‘Settings menu’ scroll down to ‘Advanced settings’ and push ‘enter’. Highlight ‘Off set’ and push ‘enter’. Use th e ‘up and ‘down arrows to change th e +/- symbol. ACT-7 QUICK START GUIDE...
  • Page 11 Press ‘enter’ to move onto th e next digit. When ‘enter’ is pressed on th e fi nal digit, th e value is stored. ACT-7 QUICK START GUIDE...
  • Page 12: Setting Th E Language

    In th e ‘Advanced menu’ scroll down to ‘Language’ and push ‘enter.’ Language Menu Use th e ‘up’ and ‘down’ arrows to select th e desired English language. Francais Deutsch Push ‘enter’ to save th e changes. ACT-7 QUICK START GUIDE...
  • Page 13: Turning Off

    Remove th e fi lter, vacuum excess dirt, and wash it with soapy water. Leave th e fi lter to dry before refi tting it and operating th e ACT-7. Push cover up...
  • Page 14: Troubleshooting

    Reset alarm as described in resetting alarms section pressure trip. on page 8. No water or kinked hoses. Top up th e ACT-7 room unit header tank with water/ glycol mixture. Insuffi cient water. External heat exchanger unit mounted in very high ambient...
  • Page 15 ACT-7 QUICK START GUIDE...
  • Page 16 Calorex Heat Pumps Limited, The Causeway, Maldon, Essex CM9 4XD, United Kingdom t. +44 (0)1621 857171 e. service@calorex.com www.calorex.com...